background image

4 LPM

14 LPM

Tip Colour

APPROXIMATE DILUTIONS

AT 40 PSI FOR WATER-THIN PRODUCTS (1.0 CP)

Orifice

Std. Drill

Size

Number)

Ratio (per Eductor Flow)

No Tip

.187

(3/16)

3:1

6.5:1

Grey

.128

(30)

3:1

6.5:1

Black

.098

(40)

3:1

7:1

Beige

.070

(50)

4:1

10:1

Red

.052

(55)

5:1

16:1

White

.043

(57)

7:1

20:1

Blue

.040

(60)

8:1

24:1

Tan

.035

(65)

10:1

30:1

Green

.028

(70)

16:1

45:1

Orange

.025

(72)

20:1

56:1

Brown

.023

(74)

24:1

64:1

Yellow

.020

(76)

32:1

90:1

Aqua

.018

(77)

38:1

128:1

Purple

.014

(79)

64:1

180:1

Pink

.010

(87)

128:1

350:1

Metering Tip Selection:

The final concentration of the dispensed solution is
related to both the size of the metering tip opening and
the viscosity of the liquid being siphoned. For water-
thin products, the chart at right can be used as a
guideline. If product is noticeably thicker than water,
consult the Measurement of Concentration Proce-
dure below to achieve your desired water-to-product
ratio. Because dilution can vary with water tempera-
ture and pressure, actual dilution achieved can only be
ascertained by using the Measurement of Concentra-
tion Procedure. The clear, undrilled tip is provided to
permit drilling to size not listed should you need a
dilution ratio that falls between standard tip sizes.

NOTE:

 A 4 LPM eductor is grey; a 14 LPM eductor is

yellow. Refer to parts diagram if unfamiliar with names
of system components.

Measurement of Concentration:

You can determine the dispensed water-to-product
ratio for any metering tip size and product viscosity. All
that is required is to operate the primed dispenser for
a minute or so and note two things: the amount of
dispensed solution, and the amount of concentrate used in preparation of the solution dispensed. The water-to-product ratio
is then calculated as follows:

Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount of Concentrate Drawn

Amount of Concentrate Drawn

Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If  the test does not yield the desired ratio, choose
a different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration. Contact your
concentrate supplier for further information on these alternative methods and the materials required to perform them.

AccuDose Parts Diagram:

5

7

8

4

2

3

1

6

1

238100

Strainer washer

2

10082835 Swivel collar

3

10082806 Swivel stem

4

10075911 Hex nipple
10075950 O-ring (two per nipple)

5

10075925 Pipe plug

6

10080710 Button, dark grey (standard)
10080711 Button, sky blue
10080712 Button, red
10080713 Button, green
10080714 Button, light grey
10080715 Button, yellow

7

10080895 Cabinet

8

10020700 Selector valve grommet
10020900 Back up ring for grommet

9

10075980 Valve parts kit

a. diaphragm, b. armature,
c. spring, d. valve bonnet

10

10079010 Spring

11

10079000 Magnet

12 a 160GB

4 LPM Eductor assembly

b 161GB

14 LPM Eductor assembly

c 3401-R

Eductor hose barb only

13 a 10070170 4 LPM inner discharge tube

b 10070470 14 LPM inner discharge tube

14 a 10064794 4 LPM outer discharge tube (18cm)

b 10077315 14 LPM outer discharge tube (1.2 m)

Description

Part No.

Key

Содержание AccuDose 3876GBA-2

Страница 1: ...n the selector valve and on the eductor 6 Placefootvalveendsofsupplytubesintoconcentratecontainers REMEMBERTOCHECKFOOTVALVESTRAINERS PERIODICALLYFORCLOGGING CLEANIFNECESSARY 7 A short discharge tube is used with the 4 LPM eductor selector valve minimum tube length is 20 cm for correct operation A longer tube 1 2 m is used with the 14 LPM eductor Slide end of tube over inner discharge tube and onto...

Страница 2: ...etering tip size and product viscosity All that is required is to operate the primed dispenser for a minute or so and note two things the amount of dispensed solution and the amount of concentrate used in preparation of the solution dispensed The water to product ratio is then calculated as follows Dilution Ratio X 1 where X Amount of Mixed Solution Amount of Concentrate Drawn Amount of Concentrat...

Страница 3: ...80723 Hose hook green 10080724 Hose hook light grey 10080725 Hose hook yellow Hose hooks are for 14 LPM discharge tubes 16 10080920 Selector valve replacement kit e Suction stub f O ring g selector valve assembly 17 690014 Metering tip kit 18 500870 Tubing 6mm x 2 1 m 19 509900 Weight 20 10076301 Foot valve Viton EPDM also available Order 10076302 NOT SHOWN 641750 Security screws for cabinet sides...

Страница 4: ... hose barb ensure inner discharge tube innerdischargetube is installed and has flooding ring e Concentratecontainerempty e Replace with full container f Inlet hose barb not screwed f Tighten butdonotovertighten intoeductortightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer h Selector out of position h Assure selector is in position desired 3 Excess concentrate d...