Troubleshooting Chart:

* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit which

are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To
remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner.
Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit.
Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then
flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into
concentrate.

1. No discharge

a. No water

a. Open water supply

b. Magnetic valve not functioning

b. Install valve parts kit

c. Excessive water pressure

c. Install regulator if water pressure

exceeds 4.28 Bar (flowing)

d. Eductor clogged

d. Clean* or replace

2. No concentrate draw

a. Clogged foot valve

a. Clean or replace

b. Metering tip or eductor has

b. Clean (descale)* or replace

scale build-up

c. Low water pressure

c. Minimum 1.76 Bar (with water running)

required to operate unit properly

d. Discharge tube(s) not in place

d. Push tube firmly onto eductor discharge

or flooding ring missing

hose barb; ensure discharge tube
has a flooding ring.

e. Concentrate container empty

e. Replace with full container

f. Inlet hose barb not screwed

f. Tighten, but do not overtighten

into eductor tightly

g. Clogged water inlet strainer

g. Disconnect inlet water line and clean

strainer

h. Selector out of position

h. Ensure selector is in position desired

3. Excess concentrate draw

a. Metering tip not in place

a. Press correct tip firmly into barb on

eductor

b. Chemical above eductor

b. Place concentrate below the eductor

4. Failure of unit to turn off

a. Water valve parts dirty or

a. Clean* or replace with valve parts kit

defective

b. Magnet doesn't fully return

b. Make sure magnet moves freely.

c. Push button stuck

c. Remove button and clean cabinet/button

to remove any dirt lodged in slide recess

5. Excess foaming in discharge a. Air leak in pick-up tube

a. Put clamp on tube or replace tube if brittle

Solution

Cause

Problem

10084449

Hydro Systems Europe Ltd

 Unit 3, The Sterling Centre, Eastern Road, Bracknell, Berks RG12 2PW  UK

Tel: +44 (0)1344 48 88 80
Fax: +44 (0)1344 48 88 79
www.hydrosystemseurope.com

Содержание AccuDose 3874GB-2

Страница 1: ...is used with a 4 LPM grey eductor Model 3875GB 2 minimum tube length is 20 cm for correct operation A longer tube 1 2 m is used with a 16 LPM yellow eductor Model 3874GB 2 Slide end of tube over eductor discharge outlet The hose hook supplied with Model 3874GB 2 may be installed on the long tube to allow it to hang from dispenser when not in use 7 Replace cabinet cover Push the sides in behind the...

Страница 2: ... calculated as follows Dilution Ratio X 1 where X Amount of Mixed Solution Amount of Concentrate Drawn Amount of Concentrate Drawn Dilution Ratio then equals X parts water to one part concentrate X 1 If the test does not yield the desired ratio choose a different tip and repeat the test Alternative methods to this test are 1 pH using litmus paper and 2 titration Contact your concentrate supplier f...

Страница 3: ...Hose hook dark grey std 10080731 Hose hook sky blue 10080732 Hose hook red 10080733 Hose hook green 10080734 Hose hook light grey 10080735 Hose hook yellow Hose hook provided with Model 3874GB 2 only 16 10061100 Support 17 10080920 Selector valve replacement kit e Suction stub f O ring g selector valve assembly 18 690014 Metering tip kit 19 500870 Tubing 6mm x 2 1 m 20 509900 Weight 21 10076301 Fo...

Страница 4: ...cale build up c Low water pressure c Minimum 1 76 Bar with water running required to operate unit properly d Discharge tube s not in place d Push tube firmly onto eductor discharge or flooding ring missing hose barb ensure discharge tube has a flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightl...

Отзывы: