background image

Installation and Operation:

1. Remove cabinet cover.  Drill holes for the three wall anchors with a 8mm drill bit, using the cabinet back as a template

for proper spacing of the mounting screws. Install mounting anchors, and then screws in top two anchors. Slide
key holes in cabinet back over screw heads, tighten screws, then install bottom screw. Do not mount more than
1.8 meters above the bottom of the concentrate container, nor below the highest concentrate level (never mount the
concentrate container higher than the proportioner).

2. Select metering tips (up to 4) for the selector valve (see next two sections). Push each tip firmly into a separate hose

barb extending from the selector valve. A tip with no hole (clear plastic colour) can be used to block any valve port not
being used. (This may be used for dispensing water only.)

3. Attach the chemical suction tube assembly to the selector valve, sliding an open end of each piece of tubing over one barb

on the valve. Ensure suction tubes are on the barbs far enough to prevent air from leaking into tube.

4. Slide tubes from each side through the notch in the cabinet.
5. Place foot valve end of supply tube assembly into concentrate container. REMEMBER TO CHECK FOOT VALVE

STRAINER PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY.

6. A short discharge tube is used with a 4 LPM (grey) eductor – Model 3872GB-2 ; minimum tube length is (20 cm) for correct

operation. A longer tube (1.2 m) is used with a 16LPM (yellow) eductor – Model 3871GB-2. Slide end of tube over eductor
discharge outlet. The hose hook supplied with Model 3871GB-2 may be installed on the long tube to allow it to conveniently
hang from dispenser when not in use.

7. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided

may be installed in the holes in the cabinet sides to prevent easy removal of cover.

8. Connect water supply hose of at least 13mm ID to water inlet swivel. (Minimum 1.76 Bar pressure, 

with water running

,

is required for correct operation.) Connect opposite end of hose to water supply. Turn water supply on.

9. Purge air from the system by depressing the buttons briefly. There may be some water discharge from the eductor

vents until the air is purged.

10. Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled). Then push

the button whenever dispensing is desired, and release button to stop flow of solution. If you wish to be able to lock
the button in the "on" position: Clip or bend the two tabs behind the lower front  portion of the button. (See diagram below)
This allows the button to be fully depressed and allows it to latch in the "on" position. 

TO UNLOCK, PULL THE BUTTON

OUT.

11.

It is essential that the discharge hose is not obstructed. If discharge is restricted, water will flow out of the
eductor vents. Do not start to operate the dispenser with liquid in the discharge tube.

AccuDose

 Series Proportioner

Models 3871GB-2 & 3872GB-2

Package Should Contain:

1. Proportioner unit.
2. Chemical inlet tubing

assembly with foot valve
& weight.

3. Discharge tube.
4. Metering tip kit.
5. Mounting hardware.
6. Hook for discharge tube

(Model 3871GB-2 only).

7. Instruction sheet.

Clip or
bend
these
tabs to
depress
button
into locked
position.

Содержание AccuDose 3871GB-2

Страница 1: ...et ThehosehooksuppliedwithModel3871GB 2maybeinstalledonthelongtubetoallowittoconveniently hang from dispenser when not in use 7 Replace cabinet cover Push the sides in behind the latch holes to snap the cover in place The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover 8 Connectwatersupplyhoseofatleast13mmIDtowaterinletswivel Minimum1 76Barpr...

Страница 2: ... follows Dilution Ratio X 1 where X Amount of Mixed Solution Amount of Concentrate Drawn Amount of Concentrate Drawn DilutionRatio then equalsXpartswatertoonepartconcentrate X 1 If thetestdoesnotyieldthedesiredratio choose adifferenttipandrepeatthetest Alternativemethodstothistestare1 pH usinglitmuspaper and2 titration Contact your concentrate supplier for further information on these alternative ...

Страница 3: ...0 Hose hook dark grey std 10080731 Hose hook sky blue 10080732 Hose hook red 10080733 Hosehook green 10080734 Hosehook lightgrey 10080735 Hosehook yellow Hose hook provided with Model 3871GB 2 only 16 10061100 Support 17 10080920 Selectorvalvereplacementkit e Suction stub f O ring g selector valve assembly 18 690014 Meteringtip kit 19 a 10068730 Tubing 6mm x 63 5mm b 10062550 Tubing 6mm x 600mm c ...

Страница 4: ...ischarge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer h Selector out of position h Assure selector is in position desired 3 Excess concentrate draw a Metering t...

Отзывы: