Hydro AccuDose 3833HFA-2 Скачать руководство пользователя страница 2

4LPM

14 LPM

Tip Colour

APPROXIMATE DILUTIONS

AT 2.86 BAR FOR WATER-THIN PRODUCTS (1.0 CP)

Orifice

Std. Drill

Size

Number)

Ratio (per Eductor Flow)

No Tip

.187

(3/16)

3:1

3.5:1

Grey

.128

(30)

3:1

4:1

Black

.098

(40)

3:1

4:1

Beige

.070

(50)

4:1

8:1

Red

.052

(55)

5:1

14:1

White

.043

(57)

7:1

20:1

Blue

.040

(60)

8:1

24:1

Tan

.035

(65)

10:1

30:1

Green

.028

(70)

16:1

45:1

Orange

.025

(72)

20:1

56:1

Brown

.023

(74)

24:1

64:1

Yellow

.020

(76)

32:1

90:1

Aqua

.018

(77)

38:1

128:1

Purple

.014

(79)

64:1

180:1

Pink

.010

(87)

128:1

350:1

Metering Tip Selection:

The final concentration of the dispensed solution is
related to both the size of the metering tip opening and the
viscosity of the liquid being siphoned. For water-thin
products, the chart right can be used as a 

guideline

. If

product is noticeably thicker than water, consult the
Measurement of Concentration Procedure below to
achieve your desired water-to-product ratio. Because
dilution can vary with water temperature and pressure,
actual dilution achieved can only be ascertained by using
the Measurement of Concentration Procedure. The clear,
undrilled tip is provided to permit drilling to size not listed
should you need a dilution ratio that falls between standard
tip sizes.

Measurement of Concentration:

You can determine the dispensed water-to-product ratio
for any metering tip size and product viscosity. All that is
required is to operate the primed dispenser for a minute
or so and note two things: the amount of dispensed
solution, and the amount of concentrate used in
preparation of the solution dispensed. The water-to-
product ratio is then calculated as follows:

Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount of Concentrate Drawn

Amount of Concentrate Drawn

Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If  the test does not yield the desired ratio, choose
a different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration. Contact your
concentrate supplier for further information on these alternative methods and the materials required to perform them.

7

5

6

8

4

2

3

1

AccuDose Parts Diagram:

3-button unit illustrated

Содержание AccuDose 3833HFA-2

Страница 1: ...of discharge tube over eductor discharge outlet and IDT Hook may be installed to allow discharge tube to hang from dispenser when not in use 8 Replace cabinet cover Push the sides in behind the latch holes to snap the cover in place The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover 9 Connect water supply hose of at least 13mm ID to water in...

Страница 2: ...achieved can only be ascertained by using the Measurement of Concentration Procedure The clear undrilled tip is provided to permit drilling to size not listed shouldyouneedadilutionratiothatfallsbetweenstandard tip sizes Measurement of Concentration You can determine the dispensed water to product ratio for any metering tip size and product viscosity All that is required is to operate the primed d...

Страница 3: ...10075980 Valve parts kit a diaphragm b armature c spring d valve bonnet 10 10079010 Spring 11 10079000 Magnet 12 a 160GB 4 LPM Eductor assembly b 161GB 14 LPM Eductor assembly c 440101 Suction stub only 13 a 10070170 4 LPM inner discharge tube b 10070470 14 LPM inner discharge tube 14 a 10064794 4 LPM outer discharge tube 18cm b 10077315 14 LPM outer discharge tube 1 2 m 15 10080720 Hose hook dark...

Страница 4: ...arge or flooding ring missing from hose barb ensure inner discharge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer 3 Excess concentrate draw a Metering tip not in...

Отзывы: