1)   

Place the tub in the exact position of final installation. The bathtub cannot be repositioned once it is

        plumbed and installed. The tub is designed to sit on top of the finished floor, however, you may need to
        leave an area by the drain open until installation of the drain is complete.

2)   

Ensure location is structurally sound, flat and level.

3)

    Elevate the tub to allow access to the bottom of the tub from the drain to the overflow area. The tub is

        very heavy; use appropriate supports.

4) 

   Temporarily “dry fit” the drain kit and trim the pipes to proper length. Note the distance from the edge of

        the tub to the center of the overflow pipe. This measurement will be used to verify the location of the hole
        in the floor for the overflow pipe. Also see rough-in dimensions on previous page.

5)

    Remove the drain kit from the tub.

6)

    Use emery cloth, grinder or wire brush to remove the plated finish from the pipe where it will be soldered  

        to the ‘tee’.

7)

    Provide opening in floor below drain of approximately 6” x 6”. This will be completely covered by the tub.

8)

    Install tub in precise location desired. Use only 100% clear silicone to adhere tub to floor.

9)

    Using the distance noted in step #4, drill hole in floor for overflow pipe.

10)

  Re-assemble drain kit on tub using clear silicone under drain strainer. Remove excess silicone immediately.

        Tighten waste flange assembly and ferrule until seated plus 1/4 turn. Remember to install bell flange on overflow
        pipe. Slide the bell flange high up on the overflow pipe to avoid heat damage during the next step.

11)

 Carefully solder connections at brass ‘tee’. Wrap a wet rag around overflow pipe to prevent the heat from

        damaging the plating. Always use proper heat shielding to protect the surrounding materials.

12)

 Connect the ‘P-trap’ to the drain kit.

13)

 Use clear silicone to seal the gap between the overflow pipe and the floor. Lower bell flange to the floor.

        Attach overflow cover and thread stopper assembly into waste flange.
        Fill tub to overflow and allow water to stand for 30 minutes. Check carefully for any leaks. NOTE: The overflow
        is a plumbing device designed to prevent water from reaching a certain level in your tub. DO NOT, under  
        any circumstances, tape off or block the overflow in any way.

Note: This is a sub floor drain. Access from below tub is recommended for installation. If there is no access from  
below, the installation is more difficult. Clearance for the drain will be required and the floor near the overflow will
need to be completed after the drain is installed. See picture below.
Drain kit parts breakout is shown in illustration to the right.

INSTALLATION INSTRUCTIONS FOR SOAKING WITHOUT PEDESTAL

Hydro Systems recommends using clear 100% silicone sealant, DO NOT use plumber’s putty.

TOWER

A Tower can be added to any of our Metro Bathtubs allowing 
you to use traditional Roman faucets.

WASTE AND OVERFLOW

  The Metro Collection offers integral waste and overflow on all models.

    Use care when selecting your drain kit. The Metro Collection offers toe tap hardware standard. 

Содержание Metro Collection

Страница 1: ... USER MAINTENANCE INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING WHEN USING YOUR HYDRO SYSTEMS TUB BASIC PRECAUTIONS SHOULD BE FOLLOWED SEE BELOW Read all instructions before proceeding with installation Inspect the tub before installation If any damage or defects are found do not install the tub If the tub is not the right size model or color do not install the tub Contact tech support at 661 775...

Страница 2: ...ring and withstands stains better than the other materials To keep this high quality look on your Metro tub please follow these instructions MATTE FINISH Remove dust with a soft damp cloth for example microfiber or calico cloths Clean surface with water and any mild detergent or dish soap For a more difficult stain such as oil paint ink or grease clean with rubbing alcohol and dry with a soft clot...

Страница 3: ... Apply plumbers putty around the Drain Body and pass it thrugh the drain hole Figure 3 Apply rubber gasket and slide it over the bottom of the Drain Body Figure 3 Slide the rubber washer over the drain body Attach the drain Body to the ABS PVC Shoe fitting and tighten until the Gasket has created a seal with the bottom of the bathtub DO NOT OVERTIGHTEN Figure 4 6 7 8 9 FIGURE 3 FIGURE 4 FIGURE 5 P...

Страница 4: ...17 FIGURE 8 FIGURE 6B FIGURE 6A INSTALL BATHTUB Apply generous bead of adhesive or silicone to the bottom of the tub supports Figure 6A Then apply a bead of tub and tile caulk or silicone around the edge of the base Figure 6B 16 14 15 FIGURE 7 Carefully set tub into position Figure 7 and connect the drain harware previously installed Please refer to www hydrosystem com for specific dimensions on y...

Страница 5: ...s It is not recommended that the blower be mounted over 8 feet away from the tub The supplied wiring between the tub and the blower is approximately 10 feet long Remote blower locations There are several locations where the blower can be located There must be a GFCI electrical outlet within 2 feet of the blower The blower is approximately 9 25 inches long and 8 inches in diameter and 5 high Substa...

Страница 6: ...install bell flange on overflow pipe Slide the bell flange high up on the overflow pipe to avoid heat damage during the next step 11 Carefully solder connections at brass tee Wrap a wet rag around overflow pipe to prevent the heat from damaging the plating Always use proper heat shielding to protect the surrounding materials 12 Connect the P trap to the drain kit 13 Use clear silicone to seal the ...

Страница 7: ... WARRANTY OBLIGATIONS OF HYDRO SYSTEMS INC Should a defect in workmanship and or material in any item covered by this warranty become evident during the term of the warranty then upon the consumer following the procedures set forth below HYDRO SYSTEMS INC at its opinion will repair or replace such item at its own cost and expense HYDRO SYSTEMS INC is not however responsible under this warranty for...

Страница 8: ...awings or improper installation 3 Problems resulting from abuse misuse negligence or accident by any party other than HYDRO SYSTEMS INC such as but not limited to damage to parts by installers 4 Problems resulting in whole or part from alteration or modification of these products by any party 5 Metal failures due to chemical corrosion This warranty is provided to you as part of your purchase order...

Отзывы: