16
3.OO programming
(continued)
3.1O Upload/Download
1) Click on Upload/Download in the left-hand
column, the page shown will open.
2) From this screen you can upload the settings
you have entered within the programmer on your
computer/tablet etc or download from the unit.
3) Click on Save at the bottom of the page.
Upload/Download
3.11 Manual Dosage
1) Click on Manual Dosage in the left-hand column,
the page shown will open.
2) From this page you can enter the desired product,
dosage, machine and whether you want flush to
create a manual dosage.
3) Clicking on Start will begin the dosage.
Manual Dosage Settings
2) Type – choose whether you want to calibrate a
product or water.
3) Product/channel – select the product you want to
calibrate or the channel for water.
4) Destination machine – choose which machine you
want to calibrate to at the point of inlet. Although
currently you must choose a washer extractor, a
3-way valve can be installed to make the physical
calibration easier.
5) Click on validate parameters to obtain KF value
and Flow rate. (
CAUTION!
ALWAYS press
“Validate Parameters” before pressing the
calibration button, even if you want to re-calibrate
after having cleaned the channel, without entering
a real volume.)
6) Place chemical drum on measuring scales and Tare to obtain zero. Initiate by holding the calibration button, use the amount
grams obtained on the measuring scales calculating exact dosage by using the specific gravity (SG) of the product.
(
Note:
Chlorine’s SG is higher than most standard products.)
7) Insert real obtained value and save.
8) Repeat for all products
3.12 Calibration
1) Click on Calibration in the left-hand column, the
page shown will open.
Calibration Settings