49
Page
Owner's Guide
Remote
Green
LED
Malfunction
descrip
tion
Diagnosis
391
Two Times
Air-fuel ra
tio
rod
failure
•
Check for c
onnection/b
reakage of wires (Part #709)
and
/
or soot on the AFR rod (Part #108).
441
Two Times
Flow sensor failure
(Easy-Link System only)
•
Check for c
onnection/b
reakage of wires and
/
or
debris
on the
fl
ow sensor impeller (Part #402).
510
Six Times
Abnormal
main gas
solenoid valve
•
Check for connec
tion/b
reakage of wires (Part #708)
and
/
or
bu
rn marks on the computer
boa
rd (Part #701).
551
Six Times
Abnormal
gas
solenoid valve
•
Check for connec
tion/b
reakage of wires (Part #708)
and
/
or
bu
rn marks on the computer
boa
rd (Part #701).
611
Four Times Fan motor fault
•
Check for c
onnection/b
reakage of wires, dust
buildup
in the fan motor (Part #103) and
/
or
burn
marks on
the computer
boa
rd (Part #701).
•
Check for frozen
/
corrosion of connectors (Part #103).
651
Four Times Flow adjustment
valve fault (Easy-
Link System only)
•
r
o
f
,
)
2
0
4
#
t
r
a
P
(
e
v
l
a
v
t
n
e
m
t
s
u
j
d
a
w
o
lf
e
h
t
t
c
e
p
s
n
I
c
onnection/b
reakage of wires, locked motor drive
due to scale
buildup,
and
/
or water leakage.
661
Four Times Bypass valve fault
•
Inspect the
b
ypass valve (Part #403), for c
onnection/
b
reakage of wires, locked motor drive due to scale
buildup,
and
/
or water leakage.
701
One Time
Computer
boa
rd fault
•
Check for c
onnection/b
reakage of wires (Part #714).
711
One Time
Gas solenoid valve
drive circuit failure
•
Refer to the 111 and 121 error codes.
721
Six Times
False
fl
ame
det
ection
•
Check if condensate drain is installed on the vent
collar of the
micro-boiler
.
•
Check if there is leaking from heat exchanger (Part #401).
741
N
/
A
Miscommunica
tion
b
etween micro-
boiler
and remote
controller
•
Check the model type of the remote controller.
•
Inspect the c
onnections
b
etween the
micro-boiler
and remote controller.
•
Check the power supply of the
micro-boiler
.
751
N
/
A
Miscommunica
tion
b
etween
micro-boiler
and temperature
controller
•
Inspect the c
onnections
b
etween the
micro-boiler
and temperature controller.
•
Check the power supply of the
micro-boiler
.
761
N
/
A
Miscommunica
tion
in Easy-Link System
•
Check if the c
onnections
b
etween the parent unit
and the child units are correct. Refer to p. 28-31.
941
Five Times
Abnormal
exhaust
temperature
•
Check if the set temperature is higher than 140°F
(60°C) and the system is Recircula
tion.
991
Five Times
Imperfect
c
ombu
s
tion
•
Check the gas type of the
micro-boiler
.
•
Inspect the environment around the
micro-boiler
.
Determine how long the unit has
been
installed.
•
Check the
altitude/
eleva
tion
of the area of where
the
micro-boiler
is installed.
•
Check if there is any
bloc
kage in the intake air
and/
or exhaust.
•
If the
micro-boiler
is installed as a direct-vent system,
check whether there is enough distance
b
etween the
intake air terminal and the exhaust terminal.
•
Check if there is grease and
/
or dirt in the
bu
rner (Part
#101) and the fan motor (Part #103), especially if the
micro-boiler
has
b
een installed in a contaminated area.