hydro-s 7024510 Скачать руководство пользователя страница 1

 

 

 

Swimming Pool Heat Pump 

 

 
 

Installation and User Manual 

 

 

 

 

 

 

 

Models: 

7024510 Hydro-S heat pump Type A5/32 

7024511 Hydro-S heat pump Type A7/32 

7024512 Hydro-S heat pump Type A10/32 

7024513 Hydro-S heat pump Type A13/32 

 

 

Содержание 7024510

Страница 1: ...ming Pool Heat Pump Installation and User Manual Models 7024510 Hydro S heat pump Type A5 32 7024511 Hydro S heat pump Type A7 32 7024512 Hydro S heat pump Type A10 32 7024513 Hydro S heat pump Type A13 32 ...

Страница 2: ... 2 SAFETY INSTRUCTIONS 3 ACCESSORIES 5 DIMENSIONS 6 EXPLODED VIEW 7 INSTALLATION 9 CONTROLLER 11 PARAMETER CHECKING AND ADUSTMENT 12 WIRING DIAGRAM 14 SPECIFICATIONS 16 MAINTENANCE 17 TROUBLESHOOTING 18 Please read carefully ...

Страница 3: ... swimming pool heat pump can lengthen your swimming season and gives you comfort at high level You will enjoy swimming not only in summer but also in spring autumn and even winter time Features Ecological and economical heating Using the renewable energy from the outdoor air it consumes less energy with low carbon emission Use advanced environmental friendly refrigerant R32 without destroying on O...

Страница 4: ...ly suitable for earthed sockets connection voltage 220 240 V 1Ph 50Hz The following safety precautions should always be taken into account Be sure to read the following WARNING before installing the unit Be sure to observe the CAUTIONS specified here as they include important items related to safety After reading these instructions be sure to keep it in a handy place for the future reference WARNI...

Страница 5: ...supply If there is no suitable earthed wall socket available it should be installed by a recognized professional electrician Do not move and repair the unit by yourself Before proceeding with any maintenance service or repairing work the product must be isolated from the mains electrical supply Only qualified personnel could carry out these tasks Improper movement or repairing the unit could lead ...

Страница 6: ...cal shock or fire Do not put your fingers or others into the fan or evaporator The ventilator runs at high speed it could cause serious injury ACCESSORIES Before starting the installation please make sure that all accessories are collected from the unit package Packing list Item Image Quantity Swimming pool heat pump 1 Operation and Installation Manual This manual 1 Inlet and outlet water pipe con...

Страница 7: ...IMENSIONS Unit mm A5 32 A7 32 A10 32 A13 32 A 816 816 912 912 B 556 556 718 718 C 315 315 375 375 D 352 352 425 5 425 5 E 124 124 135 135 F 600 600 624 624 G 71 71 96 96 H 105 105 121 121 I 280 280 370 370 ...

Страница 8: ... 3 Air side heat exchanger 1 15 Low pressure switch 1 4 Motor bracket 1 16 Handle 1 5 Motor 1 17 Controller 1 6 Axial fan 1 18 Needle valve 1 7 Front panel 1 19 Water flow switch 1 8 Grille 1 20 Titanium heat exchanger 1 9 Chassis 1 21 E box ass y 1 10 Compressor 1 21 1 Capacitor 1 11 Fixing plate 1 22 Cover E box 1 ...

Страница 9: ... 1 2 Cover E box 1 13 Right panel 1 3 Air side heat exchanger 1 14 Handle 1 4 Motor bracket 1 15 Low pressure switch 1 5 Motor 1 16 Controller 1 6 Axial fan 1 17 Titanium heat exchanger 1 7 Front panel 1 18 Water flow switch 1 8 Grille 1 19 Needle valve 1 9 Right panel front 1 20 E box ass y 1 ...

Страница 10: ... to allow access to operate controller Make sure that the outlet air will not be breathed in To perfect your installation Avoid directing the flow of ventilated air towards a sensitive noise zone such as room s window Avoid positioning pool heat pump on a surface that can transmit vibrations to dwelling Try to avoid placing appliance under a tree or exposed to water or mud which would be likely to...

Страница 11: ... the connections have been made and checked the following steps must be taken 1 Turn on the filter pump Check for leaks and make certain that the water flows from and to the swimming pool 2 Connect the power supply to the heat pump and press the ON OFF button The appliance will start up after the time delay see below has elapsed 3 After a few minutes check whether the air being expelled from the a...

Страница 12: ...this key for 5s to enter normal working status of the unit In setting or query interface press this key to exit the interface and store corresponding parameters 2 SET Confirmation Record query 1 On the home screen press this key to enter the status parameter query interface Hold this key for over 5s to enter the parameter setting interface 2 In the parameter query interface press this key to set p...

Страница 13: ...nd DOWN to check parameters No Parameter Description 1 Return water temperature Outdoor ambient temperature 30 C to 70 C 2 Ambient temperature Condenser pipe temperature 30 C to 70 C 3 Load startup signal Value 0 indicates load disabled while value 1 indicates load enabled PARAMETER CHECKING AND ADUSTMENT Parameter setting Hold SET to enter the parameter setting interface The first x starts to bli...

Страница 14: ...is reported If T1 is detected lower than 40 C for consecutive 5s the fault of T1 sensor open circuit is reported In either case the load automatically stops running The fault automatically recovers Shutting down or mode switching cannot clear the fault T2 sensor fault When T2 sensor is disabled the corresponding control logic and troubleshooting are invalid If the thermostat detects that T2 is hig...

Страница 15: ...aults because low voltage switches and temperature sensors are connected in series this situation may be caused by refrigerant leakage It is necessary to find professional maintenance personnel WIRING DIAGRAM Please refer to the wiring diagram on the electric box A5 32 A7 32 ...

Страница 16: ... 15 A10 32 A13 32 ...

Страница 17: ...73 12 23 Setting temperature range 15 C 40 C Running temperature range 5 C 43 C Refrigerant type charged R32 0 55kg R32 0 65kg R32 0 8kg R32 1 1kg Compressor Brand GMCC Landa Input kW 0 790 0 975 1 425 1 720 Air side heat exchanger Hydrophilic aluminum Inner groove copper tube Fan motor Fan type Axial Fan size mm Φ427 139 Φ427 139 Φ522 140 Φ522 140 Motor output W 32 32 60 60 Motor input W 80 80 15...

Страница 18: ...rized drinking water for cleaning Cleaning the air system The finned heat exchanger ventilator and condensate outflow should be cleaned of contaminants leaves twigs etc before each new heating period These types of contaminants can be manually removed using compressed air or by flushing with clean water It may be necessary to remove the device cover and air inlet grid first Attention Before openin...

Страница 19: ...elines below might help to solve your problem If you cannot solve the problem consult your installer local dealer The heat pump will not run Please check whether There is supply voltage tripped fuse power failure The operating switch on the wired controller is switched on and whether the correct set point temperature has been set The set temperature level cannot be reached Please check whether The...

Страница 20: ...ts must be done in accordance with relevant local and national legislation Your product is marked with this symbol This means that electrical and electronic products shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with re...