- 23 -
NO
Part Name
ERP code
NO
Part Name
ERP code
1
Front grill
28
Pipes temperature sensor collet
111900004
2
Front panel
1110040024
29
Pipes temperature sensor
111900004
3
Fan blade
113600017
30
Back grill
1110080042
4
Fan motor
11140053
31
Ambient temperature sensor
112200141
5
Fan motor bracket
1110130030
32
Ambient temperature sensor clip
113715001
6
maintain board
1110210031
33
Top cover
1110030042
7
Base tray
1110160102
34
Compressor wiring clip
110100038
8
Compressor 110100038
35
Water flow switch
112100021
9
Temperature sensor of water-in
112200133
36
isolation panel
1110110027
10
Titanium heat exchanger
113900077
37
controller box
1110120146
11
Panel on the side
1110021029
38
Cable fixing clamp-up
12
Drainage hole plug
113700077
39
Cable fixing clamp-down
113500007
13
Suction valve
112500019
40
Terminal blocks
112000008
14
Cable joints
114000184
41
controller box cover
1110150036
15
Pressure guage
110800001
42
PC board
11220183
16
Controller 112200149
43
Capacitance clamp
1110220010
17
Waterproof box
113712001
44
Capacitance 111300014
18
Panel on the side
1110021029
45
Transformator 112200064
19
Water inlet/outlet bolt
114000015
46
Fan motor capacitance
111300002
20
Suction pipe
1117991662
47
Pillar 1110070043
21
Exhaust pipe
1117991662
48
Grill on the side
1110090019
22
Pipe (4 way valve to evaporator)
1117991662
49
4 way valve
112600001
23
Pipe (4 way valve to heat exchanger)
1117991662
50
Pipe (heat exchanger to capillary)
1117991644
24
Water inlet/outlet screw cap
113900052
51
Liquid separator
1117991644
25
Capillary 1117991662
52
low pressure protection switch
112100003
26
Collection pipes
1117991662
53
high pressure protection switch
112100011
27 Evaporator
Z1Z08Y313
10. Maintenance
(1) You should check the water supply system regularly to avoid the air entering the system and occurrence
of low water flow, because it would reduce the performance and reliability of HP unit.
(2) Clean your pools and filtration system regularly to avoid the damage of the unit as a result of the dirty of
clogged filter.
(3) You should discharge the water from bottom of water pump if HP unit will stop running for a long time
(specially during the winter season).
(4) In another way, you should check the unit is water fully before the unit start to run again.
(5) After the unit is conditioned for the winter season, he is preconize to cover the heat pump with special
winter heat pump.
(6) When the unit is running, there is all the time a little water discharge under the unit.
Содержание Pro+ 22T
Страница 1: ...Swimming Pool Heat Pump User and Service manual EnglishƔFrenchƔDutchƔGermanƔRussianƔPolish ...
Страница 20: ... 18 ...
Страница 24: ... 22 9 Exploded Diagram and Maintenance 9 1 Exploded Diagram Model 5 kw ...
Страница 46: ... 44 7 3 Comment savoir les états actuels ...
Страница 50: ... 48 9 Schéma eclaté et entretien 9 1 Schéma eclaté Modèle 5 kw ...
Страница 66: ... 64 5 2 ZWEMBAD WARMTEPOMP BEDRADING SCHEMA Hydro Pro 13 18 ...
Страница 72: ... 70 7 2 Hoe de huidige status te weten te komen ...
Страница 76: ... 74 9 Open geklapt diagram en onderhoud 9 1 Open geklapt diagram Model 5 kw ...
Страница 98: ... 96 7 2 Den aktuellen Status abrufen ...
Страница 102: ... 100 9 Explosionszeichnung und Wartung 9 1 Explosionszeichnung Modell 5 kw ...
Страница 124: ... 122 7 2 Ʉɚɤ ɭɡɧɚɬɶ ɬɟɤɭɳɢɣ ɫɬɚɬɭɫ ...
Страница 128: ... 126 9 ɉɨɞɪɨɛɧɚɹ ɞɢɚɝɪɚɦɦɚ ɢ ɨɛɫɥɭɠɢɜɚɧɢɟ 9 1 ɉɨɞɪɨɛɧɚɹ ɞɢɚɝɪɚɦɦɚ Ɇɨɞɟɥɶ 5 ɤȼɬ ...
Страница 150: ... 148 7 2 Odczytywanie bieĪącego stanu urządzenia ...
Страница 154: ... 152 9 Schemat budowy pompy 9 1 Widok urządzenia rozebranego Model 5 kw ...