4.1 Domestic Hot  Water System

The Hydro-Hot's domestic hot water system must be completely drained of
domestic water any time the heater is stored where freezing temperatures
may be experienced.

NOTE:  The Hydro-Hot can still be used for interior zone heating even if
the domestic hot water system has been drained and winterized.

CAUTION:  Not winterizing your Hydro-Hot, when freezing temperatures
are present, will result in serious damage to the Hydro-Hot's domestic
hot water system.

Follow the instructions listed below when winterizing the Hydro-Hot’s
domestic water system:

A. Completely drain the fresh water storage tank.

NOTE:  If your coach is equipped with appliances that use fresh water (i.e.
ice makers, water purifiers, etc.) follow the manufacturer's
recommendation for winterization.

B. Disconnect the domestic water demand pump's suction line from the

fresh water storage tank.

C. Attach an adequate piece of hose onto the suction side of the domestic

water demand pump.

D. Place the opposite end of the hose into an adequate supply of FDA

approved RV-Antifreeze; approximately 2 gallons will be required.

SECTION 4:  WINTERIZATION

Storage

Page 4-1

Upkeep

3.1 Maintenance Schedule
Monthly

Check the Hydro-Hot's solution of water and antifreeze to ensure that it
is at the proper level.  Do this by visually checking the coolant level in
the Hydro-Hot's Expansion Tank, Figure 1.  This should be checked
only when the Hydro-Hot is at operating temperature, HOT.

Annually

CAUTION:  Before cleaning or servicing, disconnect all power supplies.

It is ideal to have your Hydro-Hot tuned-up yearly.  A tune-up should
consist of a Fuel Nozzle and Fuel Filter replacement and a thorough
cleaning of the Combustion Chamber, if necessary.  This simple tune-up
will keep your Hydro-Hot running smoothly throughout the year. This
annual tune-up will also allow service personnel to inspect for wear and
tear of other components.

CAUTION:  Operating the Hydro-Hot’s Diesel Burner or the 120 VAC
Electric Heating Element without the water and antifreeze solution will
cause serious damage to the Heater.

SECTION 3:  MAINTENANCE

Page 3-1

Содержание HHE-200-07E

Страница 1: ...Hydro Hot Motor Coach Heating System Owner s Manual 06 02 Hydro Hot Motor Coach Heating System Owner s Manual 06 02 OWNER S MANUAL MODEL NUMBERS HHE 200 07E HHE 500 07M ...

Страница 2: ...stems Inc Warranty Department 15549 East Highway 52 Ft Lupton CO 80621 Please Mail To CUT HERE AND MAIL IN OWNER S INFORMATION Owner s Name Address City State Zip Code Telephone Coach Model Coach Date of Purchase Hydro Hot Model No Hydro Hot Serial No Vehicle Systems Warranty Department 15549 East Highway 52 Ft Lupton CO 80621 ...

Страница 3: ... unique Diesel Fired Burner and an AC powered Electric Heating Element 120 VAC These two heating sources maintain the temperature of the Hydro Hot s solution of water and antifreeze In addition the Hydro Hot has been designed to preheat the vehicle s engine prior to starting HHE 200 Model Only This optional feature provides easy engine start up whenever cool weather conditions are present Be sure ...

Страница 4: ... Model Number Page 2 2 SECTION 2 OPERATING INSTRUCTIONS 2 2 Activating The Hydro Hot Heating System Diesel Burner Turn the Diesel Control Switch ON Figure 3 This procedure will activate the Diesel Burner and the Indicator Light located on the Switch Please contact your specific motorhome manufacturer for the exact Diesel Control Switch location Allow 10 20 minutes for the System to reach operating...

Страница 5: ...tween approximately 160 190 degrees Fahrenheit So simply choose how you want to heat your coach hot water and just leave the Switch s Diesel Electric or both ON Page 2 4 SECTION 2 OPERATING INSTRUCTIONS Engine Preheat 2 5 Using the Engine Preheat System Engine Preheat HHE 200 Model Only When the Hydro Hot is at operating temperature and the Diesel and or Electric Switch s is ON follow these simple...

Страница 6: ...th the vehicle as a fire may result i e dry grassy fields DO NOT operate the Hydro Hot s Diesel Fired Burner inside an enclosed building Operating the Hydro Hot Diesel Burner or the 120 VAC Electric Heating Element without the water and antifreeze solution will cause serious damage to the Heater The Heater should be switched OFF when refueling SECTION 2 OPERATING INSTRUCTIONS Important Information...

Страница 7: ... adequate piece of hose onto the suction side of the domestic water demand pump D Place the opposite end of the hose into an adequate supply of FDA approved RV Antifreeze approximately 2 gallons will be required SECTION 4 WINTERIZATION Storage Page 4 1 Upkeep 3 1 Maintenance Schedule Monthly Check the Hydro Hot s solution of water and antifreeze to ensure that it is at the proper level Do this by ...

Страница 8: ...sent Perform this procedure for both hot and cold faucets F Remove the hose and reconnect the domestic water demand pump s suction line to the fresh water storage tank G Disconnect all electrical power supplies to the Hydro Hot during storage NOTE 1 For de winterization fill the fresh water storage tank with fresh water Open close all interior and exterior water faucets one at a time until only cl...

Страница 9: ...Voltage Fault This indicator light illuminates RED when VDC voltage is too low for the Hydro Hot properly operate The fault must be manually reset once proper voltage is restored to the VDC battery system see Low Voltage Reset Low Voltage Reset The Hydro Hot must be manually reset whenever the Low Battery Voltage Fault Indicator has been activated To reset the Electronic Controller simply depress ...

Страница 10: ...eat The GREEN light also indicates that DC power is being supplied to the interior Zone Heating Fans If any of the five indicator lights are illuminating RED this indicates an electrical overload condition short in that particular heating zone NOTE A short in either the Zone Thermostat or a particular Zone Heating Fan circuit can cause the indicator light to illuminate RED Page 6 2 SECTION 6 ELECT...

Страница 11: ...y repair authorization or for additional information please contact our Technical Support Department at 1 800 685 4298 8 AM to 5 PM Mountain Standard Time FOR HYDRO HOT MODELS SECTION 6 ELECTRONIC CONTROLLER DIAGNOSTICS Engine Preheat Pump HHE 200 Model Only This indicator light illuminates GREEN whenever the Engine Preheat Pump is activated If the light is illuminating RED this indicates an elect...

Страница 12: ...h Heating System Owner s Manual 06 02 Hydro Hot Motor Coach Heating System Owner s Manual 06 02 OWNER S SERVICE LOG Continued Date Scheduled Service Service Center Date Scheduled Service Service Center OWNER S SERVICE LOG ...

Страница 13: ...ting System Owner s Manual 06 02 Hydro Hot Motor Coach Heating System Owner s Manual 06 02 OWNER S SERVICE LOG OWNER S SERVICE LOG Continued Date Scheduled Service Service Center Continued Date Scheduled Service Service Center ...

Страница 14: ...ng Specialists Motor Coach Heating Specialists Motor Coach Heating Specialists Manufacturers and Distributors Manufacturers and Distributors Manufacturers and Distributors Manufacturers and Distributors Manufacturers and Distributors 15549 East Highway 52 Fort Lupton Colorado 80621 1 800 685 4298 Fax 303 857 9000 Copyright 2002 Vehicle Systems Inc All rights reserved www hydro hot com LTE VHS 222 ...

Отзывы: