Страница 2: ... that the equipment operates at its maximum performance level All users must read and understand this manual completely before operating the machine Always maintain this manual in legible condition adjacent to the V115 Pump out or place in a secure location for future reference Any questions pertaining to the operating or servicing of this unit should be directed to your nearest Hydro Force distri...
Страница 3: ... 28 4lbs Tank Capacity 11 gallons Pump out Pump Little Giant 115VAC 8 20 gpm Maximum psi 11 4 Maximum pumping height 26 ft Power Draw 5 00amps Waste Pump Standard Equipment V115 Pump out Tank Unit Pump out Hose 50 x 3 4 with male female garden hose fittings AH65 50 X 3 4 Pump Out Hose ...
Страница 4: ... Extension cord 12 3 x 50 NM4407 Extension Cord 12 3 x 50 AX33 Shockbuster External GFCI Protector AX126 2 Flash Cuff Male Starter Cuff AH203 AX126 SHOCKBUSTER GFCI NM4407 50 X 12 3 CORD WITH GFCI AX33 50 X 12 3 EXTENSION CORD AC11S SS FILTER SCREEN AH65 50 X 3 4 PUMP OUT HOSE AH203 2 FLASH CUFF MALE STARTER ...
Страница 5: ...he pump out Plug unit into grounded outlets only Do not remove ground prong from plug Use of a Ground Fault Circuit Interrupting GFCI device will reduce the risk of electrical shock Do not use the V115 Pump out in standing water or on wet surfaces Do not store the V115 Pump out in wet conditions If V115 Pump out is leaking unplug power cord from outlets before approaching or touching machine Do no...
Страница 6: ...eze to eliminate damage during shipment in cold weather The V115 Pump out must not be used to pump flammable or combustible materials or used in areas where these materials may be present Rinse the V115 Pump out tank and pump with fresh water after each day s use Do not allow pump to run dry Do not by pass the float switch to operate the pump Examine the pump out hose before each use and replace o...
Страница 7: ...se coming from the extractor to one of the 2 hose barbs on the outlet side of the V115 Pump out If you are using two tools the second hose can be connected to the other barb If you are only using one tool keep the rubber stopper in the second barb For 4 to the Door operation connect two 2 vacuum hoses to the barbs on the outlet side of the V115 Pump out tank A single 2 vacuum hose can run from one...
Страница 8: ...mp out discharge port fitting on the side of the tank Connect the pump out hose to the discharge port fitting Place the other end of the hose in a commode or drain connected to the sanitary sewer system Secure hose end to prevent movement during pumping When ready to begin cleaning turn the V115 Pump out power switch to the ON position Do not turn on waste pump switch unless pump out hose is conne...
Страница 9: ...maining water from hose Connect ends of hose together to prevent dirty water from dripping from hose during transport Disconnect the vacuum hoses Clean the filter screens as needed Replacement filter screens are available AC11S Empty the remaining water from the tank and rinse out the tank Disconnect the power cords from the outlets and from the machine Roll up all hoses and cords Collect and stor...
Страница 10: ...lty Replace pump out pump NM5053 Pump out pump clogged Clean pump out Clean filter screens Keep tank clean Outlet check valve stuck Clean or replace check valve Discharge hose restricted Un kink clean out or replace hose Float switch stuck Clean switch make sure float slides up down easily Float switch faulty Replace float switch NM5054 To reduce the risk of fire electrical shock or injury repairs...
Страница 11: ...11 V115 Pump out Wiring Diagram PUMP BROWN WHITE BLUE BLACK BLUE BLUE BROWN GREEN GREEN ...
Страница 12: ... better Remove the tank lid and lay the tank on its side near a drain Use a hose to rinse the dirt and debris out of the recovery tank Close the drain valve and spray the tank with a deodorizer or disinfectant Dispose of the dirty water and debris Clean the outside surface of the tank Wipe off the cord and hose Examine hose and cord after each use and repair or replace as needed CLEAN WASTE PUMP O...
Страница 13: ...ose to a drain or hold a bucket up to the fitting to catch the pump out flow 3 Remove the lid from the Pump out Turn the Pump out power switch to the ON position and lift the float switch to engage the pump out Lower the float and turn off the Waste Pump Switch as soon as you see anti freeze flowing from the outlet fitting or hose 4 Drain the remaining anti freeze solution from the tank Remove the...
Страница 14: ...14 Parts Replacementpartsavailableforrepairof yourV115Pump out Section 3 1 2 4 3 5 7 8 9 9 10 11 12 6 6A 13 9 14 15 16 ...
Страница 15: ... QTY 2 5 ft NS NM4462 CABLE CRIMPS QTY 3 6 NM4061 SCREW 10 32 X 1 2 SS BHCS 1 for Cable 6A NM4081 NUT 10 32 HEX NYLOCK SS 1 for Cable 7 NS121 LATCH HOOK QTY 2 8 NS120 LATCH QTY 2 NS NS116 RIVETS 1 8 QTY 8 9 LAC12H LABEL SET 5 PIECES 10 NM5714 ROCKER SWITCH DPST QTY 1 11 NM5051 STRAIN RELIEF 3 8 MPT QTY 3 NS NM5239B NUT STRAIN RELIEF 3 8 FPT QTY 3 13 NM4456 GASKET SWITCH BOX QTY 1 14 PUMP OUT TANK ...
Страница 16: ...16 16 7 8 9 17 18 19 9 1 3 5 9 2 4 2A 14 ...
Страница 17: ...15 GASKET ADAPTER ELBOW QTY 4 5 NM4460 CABLE Sold per foot QTY 2 5 ft NS NM4462 CABLE CRIMPS QTY 3 7 NS121 LATCH HOOK QTY 2 8 NS120 LATCH QTY 2 NS NS116 RIVETS 1 8 QTY 8 9 LAC12H LABEL SET 5 PIECES 14 PUMP OUT TANK ALUMINUM QTY 1 NS NM4464 1 X 4 ADHESIVE PADS QTY 6 15 SWITCH BOX ALUMINUM QTY 1 16 PUMP OUT LID ALUMINUM QTY 1 NS GASKET Sold per Foot QTY 5 25 ft NS PP05 008002 ADHESIVE FOR LID GASKET...
Страница 18: ...NM5239B NUT STRAIN RELIEF 3 8 FPT QTY 3 14 PUMP OUT TANK ALUMINUM QTY 1 NS NM4464 1 X 4 ADHESIVE PADS QTY 6 20 AC11S SS FILTER SCREEN QTY 2 21 NM5053 PUMP OUT PUMP QTY 1 22 NM5054 FLOAT SWITCH ASSEMBLY QTY 1 23 NM5094 ELBOW 90 3 4 STREET QTY 1 24 NM5052 CHECK VALVE 3 4 FPT QTY 1 25 BR078 NIPPLE 3 4 HEX QTY 1 ...
Страница 19: ...enance unauthorized modification chemical incompatibility misuse abuse or exposure to freezing temperature conditions It does not cover normal wear items such as filter screens hoses cords or other items which require replacement as a result of ordinary usage To obtain warranty service for the V115 Pump out contact your distributor or Hydro Force If the unit must be returned to Hydro Force or an a...