- 16 -
Troubleshooting Continued
Problem
Cause
Solution
Vacuum
Motor Not
Running
Building circuit breaker
tripped. Reset breaker or move
cord to other outlet
Building circuit breaker tripped. Reset breaker or
move cord to other outlet
Faulty power cord
Replace cord
Faulty switch or internal
wiring Check wiring & test
switch
Repair as needed *
Vacuum motor faulty
Replace vacuum motor
Loss of
Vacuum
Vacuum motor faulty
Replace vacuum motor
Vacuum motor gasket
damaged
Replace gasket
Recovery tank lid gasket
damaged
Replace lid assembly or gasket
Vacuum hose or tool clogged
Clean out vacuum hoses and tool
Vacuum hoses or cuffs leaking
Replace vacuum hoses, cuffs & connectors as
needed
Recovery tank full
Drain tank
Float shutoff filter clogged
Clean float shutoff filter
Float shutoff stuck
Repair or replace float shutoff
Recovery tank damaged
Replace recovery tank
Tool won't
spray - slow or
uneven spray
Jet clogged
Clean out or replace jet
Inline filter clogged
Clean out or replace filter if so equipped
Jet worn
Replace jet
Jet not aligned properly
Re-align jet
Tool valve faulty
Repair or replace valve
Quick connects or hoses
restricted
Clean out or replace quick connects and/or hoses
Pump not pumping
See Troubleshooting sections relating to solution
pump
Содержание O100
Страница 12: ...12 Wiring Diagrams O200H O500H O1200 ...
Страница 13: ...13 O3 200H O3 500 ...
Страница 14: ...14 O100 ...
Страница 17: ... 17 Parts List and Breakdown Olympus Sub Assemblies ...
Страница 18: ... 18 Solution Tank Assembly ...
Страница 20: ... 20 Waste Tank Assembly ...
Страница 23: ... 23 Auto Pump Out Assembly ...
Страница 25: ... 25 Base Assembly ...
Страница 27: ... 27 Vacuum Assembly ...
Страница 29: ... 29 Pump and Heater Assembly ...