![Hydro-Force Nautilus MX500HE Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/hydro-force/nautilus-mx500he/nautilus-mx500he_operating-manual_2191945008.webp)
8
Vacuum Connections
The MX500HE has a unique vacuum system which allows you to
connect your vacuums in either parallel or in series. Vacuum
connections can be changed quickly, with only a screw driver.
∗
THIS MUST BE PERFORMED BY A QUALIFIED
TECHNICIAN
While there is debate on which vacuum alignment provides the best
extraction, this much is true:
•
Two vacuums in series: The vacuum lift is increased by 1.6 times
the rating of a single vacuum, while the air flow stays the same as
a single vacuum.
•
Two vacuums in parallel: The vacuum air flow is increased by 2.0
times the rating of a single vacuum, while the lift says the same.
Air flow is usually measured in cubic feet per minute, indicated as
CFM.
Lift is usually measured in inches of water column, indicated as “H2O
or “WC.
To connect vacuums in parallel:
1.
Connect the discharge / exhaust hose from vacuum #1 to the exhaust
pipe on machine base.
2.
Place the rubber stopper into the vacuum inlet port of vacuum
manifold number two.
3.
Open vacuum gate valve and attach the Gatekeeper to prevent
accidental valve closure.
When connected in parallel, both vacuums must be running during cleaning.
Vacuums cannot be operated individually.
To connect vacuums in series:
1.
Connect the discharge / exhaust hose from vacuum #1 to the vacuum inlet port of
vacuum manifold number two.
2.
Place rubber stopper into the exhaust pipe on machine base.
3.
Remove Gatekeeper and close vacuum gate valve.
When connected in series vacuums can be operated individually if desired during cleaning.
Always secure the Gate Valve Open with the
Gatekeeper when connecting the vacuums in Parallel. Closing
the Vacuum Gate Valve with the hoses connected in the
Parallel configuration may cause damage to Vacuum
#2.
Section
2
GATEKEEPER
Содержание Nautilus MX500HE
Страница 1: ...1 LMANN13 Revised 01 29 2015 Nautilus MX500HE Operating Manual ...
Страница 36: ...36 Parts Replacementpartsavailableforrepairof yourMX500HE Section 3 KIT A PT054 KIT B PT055 KIT C PT056 ...
Страница 39: ...39 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Страница 40: ...40 Pump Out Pump AP37F PARTS ASSEMBLY ...
Страница 41: ...41 2 4 4 6 7 10 39 12 3 11 3 5 1 8 9 8 9 8 9 2 8 9 ...
Страница 45: ...45 48 49 49 47 47 47A 47A 47 47A 51 51 37 9 54 64 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS 47 47A ...
Страница 46: ...46 44 67 117 PUMP BOTTOM VIEW OF BASE 68 112 60 60 3 59 37 39 61 62 57 56 9 54 9 54 63 55 3 59 61 62 120 ...
Страница 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK ...
Страница 50: ...50 96 91 97 9 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 117 117 ...
Страница 51: ...51 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 117 9 97 ...
Страница 52: ...52 HEATER PARTS 42 42A 98 114 110 71 113 114 ...