33
Storage Prep and Freeze Protection Procedures:
Your Nautilus MX200H must be protected from freezing. Freezing can cause serious damage to the pump,
pump-out, auto-fill float valve, and any other component containing water. If the MX200H is transported or
stored in freezing temperatures, the following procedures should be performed.
ALSO, if the MX200H is stored for an extended period of time, the following procedure should be
performed to prevent the pump seals from drying out.
1.
In a separate container mix 1/2 gallon of water with 1/2 gallon of automotive radiator Ethylene Glycol
anti-freeze. (Propylene glycol can be used as a non-toxic alternative anti-freeze.). Mix well and pour into
the solution tank.
2.
Connect the solution hose to the solution outlet (female quick connect).
3.
If not equipped with the optional Auto Fill System
, snap an open quick connect onto the other end
of the hose and place the hose end back into the solution tank.
If equipped with the Auto Fill system
, connect the opposite end of the HP solution hose to the Auto-
Fill inlet (male quick connect.) Leave the chemical feed hose in the solution tank and ensure the check
valve filter is submerged in the anti-freeze solution. To speed the process the metering tip can be
removed.
4.
Turn the solution pump switch to the ON position and perform the pump priming procedure. When the
pump is primed, allow the anti-freeze to circulate for 5-10 minutes. Mix and add more anti-freeze solution
as needed. For machines with the optional Auto Fill System, make sure end of chemical feed hose stays
submerged in the anti-freeze solution. This will assure that the anti-freeze will be drawn into the
proportioning valve.
5.
Connect any cleaning tools and solution hoses that will be stored with the MX3-200. Direct tool spray
back into the solution tank or into a bucket. Repeat for all tools to be protected.
6.
Turn the solution pump switch to the OFF position.
7.
Use the vacuum hose to vacuum the remaining anti-freeze solution out of the solution tank and bucket.
8.
If so equipped, remove the cap from the waste-pump out outlet fitting on the back of the machine.
Connect a hose to a drain or hold a bucket up to the fitting to catch the pump-out flow. Remove the lid
from the recovery tank. Turn the Waste Pump switch to the ON position to engage the pump-out. Turn
off the Waste Pump Switch as soon as you see anti-freeze flowing from the outlet fitting or hose.
9.
Drain the remaining anti-freeze solution from the recovery tank and the machine is ready for storage.
RETURNING THE MX200H TO SERVICE AFTER STORAGE OR
FREEZE PROTECTION:
To return the MX200H to service, the anti-freeze must be flushed from the machine. Flush the anti-freeze
out of the machine by repeating the procedures above using fresh water in place of anti-freeze.
Содержание Nautilus MX200H
Страница 1: ...1 LMANN07 Revised 02 16 2018 Nautilus MX200H Operating Manual ...
Страница 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Страница 38: ...38 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Страница 39: ...39 1 2 5 6 7 8 9 11 3 8 9 12 4 4 3 10 39 8 9 8 9 2 ...
Страница 43: ...43 48 49 49 47 47 47A 47 47 47A 47A 51 51 37 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS ...
Страница 48: ...48 96 91 97 9 94 105 OPTIONAL PUMP OUT CONNECTIONS 99 95 93 118 118 ...
Страница 49: ...49 FLOW 81 92 91 99 96 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 9 97 9 39 118 ...
Страница 50: ...50 HEATER PARTS 111 113 114 112 2 115 2 116 2 42 42A 117 ...