1.Introduction

Thank you for purchasing  our Digital Ballast. Please review the following 

instructions to ensure you receive the best performance. Each ballast uses 

a high temperature, resin-sealed component board for completely silent 

operation without a fan. Each unit  is burned-in at the factory for approximately 

twelve hours to ensure maximum reliability.

Our Digital Ballast uses a mirco-processor similar to your home computer. 

To ensure safe operation, it is programmed or a “soft-start” and does not 

require an initial surge of power to light the lamp. This increases the lamp life 

and allows the end user to start multiple ballasts at the same time without 

tripping breakers. In case of auto-shut off, please disconnect from the power 

supply, remove the faulty lamp or check for wiring problems, then restart 

your ballast.

2.Controls, Connections and Indications

A.Digital ballast

B. Output plug

C.IEC connector for power cord

D . Power cord with NEMA 6-15 plug

NEMA 6-15

3. Product Information

3.1. Technical specifications

3.2. Main Dimension

3.3. HOT SPOT

Tcase max=75°C

3.4 Environment
The product is meant for use in climate rooms. The product may be used in 

damp environments. The product may not be used in wet environments or 

outdoors. The 630W Doubled Ended CMH Lamp functions optimal when the 

ambient temperature is between -20 ~ 40° Celsius / -4 ~ 104° Fahrenheit.

4.Wiring Diagram

-Ballast Case must be Grounded

5.Protections

1.End of Lamp Life(EOL)Protection

2.Short circuit protection

3.Open circuit protection

4.Ignition failure protection

5.Thermal protection

6.Warning

Power surge, power outage, outage overloading may stress or damage the 

lamp. As a safety feature, the Soft-Start technology also reduces ballast 

damage caused by a bulb failure. In case of an unexpected shut-off, please 

disconnect from the power supply, remove the faulty lamp, check for wiring 

problems, then plug-in the ballast power cord. 

7.Disclaimer

Any of the following circumstances will not be warrantied:
1. Product damaged due to incorrect installation of the product without 

    following the wiring diagram.

2. Damaged by improper use or submerging in water and not following the 

    manual instruction.

3. Install or use of the product without following local laws and regulations.

4. Damage due to maintenance or repair of the product by an unauthorized 

    technician.

5. Use in an environment that does not meet the provisions indicated in the 

    manual.

6. Damaged by mishandling, abnormal voltage, earthquake, flood, fire, 

    transportation accidents, etc.

IMPORTANT PRODUCT INFORMATION

READ IMMEDIATELY

SAFETY FIRST!

Failure to observe the following safety warnings may result in serious injury 

or death. Use all products only as directed. Failure to observe these safety 

warnings will result in a waiver of any and all liability on the part of its 

manufacturer, and resellers, and will void all warranties to the extent 

permitted by law.

WARNINGS AND INSTRUCTIONS

FOR USE:

• Disconnect power before re-lamping.

• When re-lamping, make sure lamp has time to cool before touching.

• Make sure power cord is connected properly.

• DO NOT hang ballast by power cord or lamp cord.

• DO NOT make contact with the interior of the socket while the power is on.

• DO NOT plug or unplug a lamp cord while the ballast is turned on.

• ALWAYS unplug the ballast from the power source before connecting or 

  disconnecting any lighting device to ballast, moving ballast, or otherwise 

  touching or handling ballast or its components.

• DO NOT use with generators. Warranty will be voided.

• NEVER stand beneath the ballast.

• NEVER put hands or any other objects in the interior of the ballast.

• DO NOT operate this or any lighting system in wet areas.

• NEVER get the ballast wet or allow it to come into contact with water or 

  any other liquids.

• NEVER drop, shake or jostle the ballast.

• NEVER attempt to insulate or otherwise cover the ballast, as it releases a 

  great deal of heat and may cause a fire or other damage. Ballasts should 

  always have plenty of room to breathe and good ventilation around them.

• DO NOT plug this system into a supply voltage other than what is 

  instructed on your fixture.

• DO NOT attempt open or rewire the components of the light system. It will 

  void the warranty and may cause serious injury or death.

• NEVER attempt to rewire or alter any internal or external mechanisms or 

  components on the ballast. This includes trying to cut and/or rewire 

  the cords.

Version

630W

3.5kg/7.72lb

75 °Celsius / 167 °Fahrenheit

-20 ~ 40 °Celsius / -4 ~ 104 °Fahrenheit

120V

5.78A

686W

>0.95

< 15%

50-60Hz
IEC C14

5 kV

≤50 Amps

Nema 6-15

240V

2.86A

270.5mmx181.5mmx102mm

Product weight

Dimensions (L*W*H)

Temperature case
Temperature ambient
Input v/-10%

Input current at 100%
Input power at 100%

Power factor

Total Harmonic Distortion

Frequency
Power inlet

Ignition voltage:
Inrush current:

Plug type:

HOT SPOT

1

5A

 1

2

5V

~

E

2

06

1

44

C

B

A

D

Page 1

Page 2

Page 3

Отзывы: