15 - CDS 4.8 SV Owner’s Guide
CDS START UP
1. Make sure the vehicle’s gear select lever is in the Park position and the emergency
brake is set. Also make sure all accessories are turned off (A/C, fan).
2. Start the vehicle’s engine.
3. Turn key on the CDS dash.
4. Select the cleaning speed appropriate for the cleaning job.
Starting in the low position is recommended due to the lower stress on the clutch
during start up.
5.
Turn on the PUMP CLUTCH switch. Adjust cleaning pressure to desired level.
6.
Turn on the PUMP IN switch (if equipped).
7.
Turn the heat control valve to ‘MAX’ only if you will be using water. Do not activate
the heat exchanger during flood extraction work.
8.
Turn the CHEMICAL SYSTEM valve to the ‘PRIME’ position to purge any air from
the system.
The prime hose is plumbed into the recovery tank. Leaving the valve in the
‘PRIME’ position will cause excessive chemical usage.
a.
When the chemical begins to flow through the flowmeter, with the flow indicator
reading maximum flow and the PRIME line pulsing, turn the CHEMICAL
SYSTEM valve to ‘ON’. Cap off vacuum if necessary.
b.
While spraying the solution from the cleaning tool, adjust the chemical flow by
turning the CHEMICAL METERING CONTROL to the desired level.
9. Optional: Turn the AWDS switch ‘ON’ if using the Automatic Pump-Out feature.
The pump will not engage until the water level rises inside the recovery tank.
10. Now proceed with the cleaning operation.
The machine will automatically shut down when the recovery tank reaches its full
capacity due to the float switch located inside the tank. When this occurs, turn
the CDS key switch off and empty the recovery tank. Then, turn the unit back on
and continue to clean.