Page 9-1: Water and Chemical
Boxxer 421
Water and
Chemical System
T
his high pressure chemical system has been designed to be simple and trouble
free.
WATER AND CHEMICAL FLOW OPERATION
The chemical pump draws the chemical from the inlet filter which is in the chemical
container. It flows through the flow meter indicating the GPH’s of chemical being
used. The chemical then flows through the chemical pump to the chemical selector
valve. The chemical valve can be used to prime the pump (evacuate air from the
system), inject chemical into the system or turn the chemical flow off. In the “ON”
position, chemical flows through the metering valve, and is injected into the heated
water path just prior to its leaving the machine.
The low water float switch in the water box, is a safety switch that is designed to
protect your system from sudden or unexpected loss of water supply. If, for ex-
ample, the water source at the house were turned off, the water level of the water
box would drop, activating the low water float switch, which automatically disen-
gages the system and prevents the water pump from running dry.
The desired chemical injection ratio may be obtained by an adjustment of the
chemical flowmeter during the spraying of water through the cleaning tool.
BEFORE CLEANING BEGINS:
1. Turn the Chemical Selector Valve to the “PRIME” position to purge any
air from the system.
If the chemical does not begin to flow through the flowmeter within
60 seconds, remove the Chemical PRIME Line (the one without the filter)
from the chemical container and insert it into the vacuum hose connection
at the front of the machine.
Содержание Boxxer 421
Страница 28: ...Page 8 23 Electrical System Boxxer 421 Figure 1 4 Hard Water Map...
Страница 31: ...Page 2 3 Cleaning and Chemicals Boxxer 421...
Страница 52: ...HydraMaster Corporation Page 6 6 High Pressure Pump Boxxer 421 Figure 6 2 HydraPump II C5043 Rev...
Страница 60: ......
Страница 73: ......
Страница 74: ......
Страница 76: ...Page 8 2 Electrical System Boxxer 421 Figure 8 1 Wiring Schematic D 5149 Rev H...
Страница 77: ...Page 8 3 Electrical System Boxxer 421 Figure 8 2 Wiring Schematic D 5148 Rev H Sheet 2...
Страница 78: ...Page 8 4 Electrical System Boxxer 421 Figure 8 3 Wiring Schematic D 5148 Rev H Sheet 3...
Страница 79: ...Page 8 5 Electrical System Boxxer 421 Figure 8 4 Wiring Schematic D 5148 Rev H Sheet 4...
Страница 84: ...Page 9 5 Water and Chemical Boxxer 421 Figure 9 2 Wiring Schematic D 5150 Rev Sheet 1 3...
Страница 85: ...Page 9 6 Water and Chemical Boxxer 421 Figure 9 3 Wiring Schematic D 5150 Rev Sheet 2 3...
Страница 86: ...Page 9 7 Water and Chemical Boxxer 421 Figure 9 4 Wiring Schematic D 5150 Rev Sheet 3 3...
Страница 94: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......
Страница 100: ......
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ...Page 11 1 Machine Assemblies and Parts List Boxxer 421 Machine Assemblies and Parts Lists...
Страница 124: ...Page 11 21 Machine Assemblies and Parts List Boxxer 421 Figure 11 18 Fuel Pump Assembly B 4627 Rev...
Страница 159: ...Page 12 1 Chemical Wand Parts Boxxer 421 Cleaning Wand Parts Figure 12 1 HydraHoe Two Jet Cleaning Wand Assembly...
Страница 166: ......