5 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
66 / 120
BeWa MFU-15E_S 4391552d en-us print
5.6 Connecting the suction/pressure port
Install the filter unit securely in a system/an assembly, take the
pressure loss into account with the piping or hose system. You
will find the respective formula to calculate the pressure loss.
The pressure loss in a hydraulic line depends upon:
– Flow
– Kinematic viscosity
– Pipe dimensions
– Fluid density
The pressure loss can be estimated as follows for mineral oil-
based hydraulic oils:
Fig. 21:
Pressure loss formula
Δp Pressure differential
[bar]
L Line length
[m]
d Internal pipe diameter
[mm]
Q Flow
[l/min]
ν Kinematic viscosity
[mm²/s]
D Density
[kg/dm³]
The mineral oil-based hydraulic oil has a density of ≈ 0.9 kg/
dm³.
This formula applies to straight pipe runs. Particularly with re-
gard to the suction side connection, note that additional con-
nectors and pipe bends increase the pressure differential.
Observe the following points for hydraulic connection:
– Keep the height difference between the pump and the oil
level in the reservoir as small as possible.
– Use a suction hose that is suitable for a vacuum of ≥
-0.5 bar (e.g. -1 bar).
– Avoid constrictions in the connected hoses. This reduces
the power and increases the risk of cavitation.
1
2
3
4
5
6
7
8
9
A
Содержание MFU-15E
Страница 119: ......
Страница 120: ...www hydac com ...