FCM Series
Disposing of the FCM
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 33 / 40
Bewa FCM 3160267d en-us 2012-01-24.doc
2012-01-24
Disposing of the FCM
After dismantling the emptied unit and separating the various materials, dispose of
the unit in an environmentally friendly manner.
Errors and troubleshooting
Error
Cause(s)
Remedy
Pronounced contamination
of the medium
Replace filter element
Contamination retention
capacity of the filter
element reached.
Replace filter element
Differential pressure > 2
bar
Viscosity too high
Warm medium up
The pump is conveying in
the wrong direction.
Check the rotational
direction of the motor and,
if necessary, reverse the
phases.
No flow
suction hose not deep
enough in the container
Sufficiently immerse the
suction hose in the
medium
No function
Not connected to power
supply.
Check the electrical
connections, such as the
plug, cables and outlet
Response of the
differential pressure relief
valve
Operating pressure over
maximum
Loud operating noise in
the pump
Suction strainer clogged
Clean the suction screen