Error messages / troubleshooting
FAM 15/30/50/70 ATEX
en(us)
Page 60 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
[H15] V-pump pressure
Step
Description
1.
Malfunction:
"V-pump pressure"
2.
Cause: the pressure in the oil separator for the vacuum pump is
too high.
3.
The air de-oiling element is used up / clogged.
3.
Replace the air de-oiling element.
4.
Press the RESET button to acknowledge/reset the fault.
4.
Does the malfunction recur after the vacuum pump has started?
-> a. Yes
-> proceed to Step 6.
5.
-> b. No
-> proceed to Step 9.
6.
The vacuum pump or the controller in the control cabinet is
defective.
7.
Repair or replace the vacuum pump or the defective parts of the
controller.
8.
Check the pressure relief valve of the evacuation pump for
proper functioning.
9.
The fault is repaired.