Error messages / troubleshooting
FAM 15/30/50/70 ATEX
en(us)
Page 52 / 96
BeWa FAM15-70 Atex 3193049h en(us) 2013-06-19
2013-06-19
[H7] Outlet (OUT) clogged
Step
Description
1.
Fault:
"Outlet clogged"
Cause: Medium cannot flow out of the vacuum column
(emptying pump pressure limit = 5 bar)
2.
Check the position of the shut-off devices in the return line. If
they are closed, then open them. Check/clean the suction
screen.
3.
Press the RESET button to acknowledge/reset the fault.
4.
Does the fault repeat after ~ 4 minutes?
-> a. Yes
-> proceed to Step 6.
5.
-> b. No
-> proceed to Step 7.
6.
Check the pressure relief valve of the evacuation pump for
proper functioning.
7.
The failure is repaired.