HYDAC FILTER SYSTEMS GMBH
Setting up / assembly / integration of the filter unit | 6
BeWa OFU 3120755e en-us print
51 / 84
6.6 Attaching / connecting the suction / pressure hoses
(Accessories)
Take into account the pressure loss when connecting suction/
pressure hoses. The suction/pressure hoses from the filter unit
Accessories list are matched to the filter unit.
NOTICE
High solid particle contamination in the fluid / at the bottom of
the tank
The pump will be damaged/destroyed
u
Do not prime fluid directly at the bottom of the tank.
u
Do not prime fluid in the sump.
The greatest contamination is found on the bottom of the tank.
All impurities and other particles are deposited on the bottom
of the tank.
Prevent aeration of the medium by fully immersing the lance
in the medium.
Make sure that the lance is always below the oil level in oper-
ation.
The
IN/OUT
connection dimensions on the filter unit can be
found in Chapter Technical data.
Check the hoses for damage and brittleness. Replace dam-
aged or brittle hoses immediately. Doing so avoids leaks dur-
ing operation.
Put the hoses with the lance, without any tension and or twist,
into the corresponding tank. Put the hose with the lance into
the corresponding tank without any tension or twist. Secure the
hose so that it cannot fall out or float.
Check that no shut-off devices in the lines/hoses are ob-
structed. Make sure there is a depressurized outlet.
1
2
3
4
5
6
7
8
9
10