FCU 8000 series
Error Messages and Troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 89/112
BEWA FCU8000 3109776d en-us 2011-06-10.doc
2011-06-10
Error Messages and Troubleshooting
Error message
Cause(s)
Remedy
Invalid parameter
You have entered a value
which is outside the
permitted value range (e.g.
NAS 23).
Display the permitted value
ranges using the keys
+
and
by scrolling
above the maximum
values. Then the minimum
value is automatically
displayed.
Check parameter
Defective parameter:
No. xx
The self-monitoring function
of the FCU has detected a
check sum error for one or
more parameters.
Cause: Strong
electromagnetic interference
has changed the
parameters.
Rest all parameters using
the keyboard or transfer
the parameters with the
FluMoS software.
Measurement ended
Memory for
measured values full
The setting for the "Memory
mode" parameter is at "Stop
if full".
The maximum number of
reports or measured values
has been reached. No more
values can be stored.
Delete the reports or set
the "Memory mode"
parameter to "Overwrite".
For details see page 52.
Value not accepted
An error occurred while
storing a value in EEPROM.
Repeat the entry or
continue the measurement.
If the fault recurs, contact
HYDAC.