7 | Operation
HYDAC FILTER SYSTEMS GMBH
82 / 148
BeWa FCU1310 3371346g en-us lq
7.3.3 Measuring in the range 5 to 345 bar /
217 to 5000 psi with oil
For the measurement of permissible oil up to 15 … 345 bar /
217 … 5000 psi, proceed as follows:
WARNING
Hydraulic systems are under pressure
Danger of bodily injury
u
The system must be depressurized before performing any
work on the product.
u
If the pressurized connection is connected to the hydraulic
system, oil will flow through the FCU.
u
Make sure that the specified sequence is followed.
NOTICE
Operating pressure exceeds 345 bar / 5000 psi
The excess pressure will be discharged via port OUTLET
u
Never seal the connection OUTLET.
u
Put the free end of the OUTLET return hose into an un-
pressurized container.
u
When operating, always observe the permissible operating
pressure.
Required hoses / adapters:
Return hose
High-pressure hose
High-pressure adapter