FluidMonitoring Module High
Pressure
FMM Features
HYDAC Filter Systems GmbH
en
Page 14 / 28
FMM Features
The FluidMonitoring Module FMMHP Series combines HYDAC's Condition
Monitoring Products ContaminationSensor CS 1000 and AquaSensor AS 1000 in
one system.
The FMMHP is used as a robust and stationary system for online measurement of
solid particle contamination and water content in hydraulic and lubricant fluids (e.g.
for the detection of leakages).
The FMMHP features all of the requisite connectors / adapters, enabling it to be
easily connected to existing hydraulic circuits.
The FMMHP is suitable for the following operating pressures:
FMMHP with pressure accumulator
15 ... 250 bar
FMMHP without pressure accumulator
15 ... 300 bar
Advantages offered by the FMMHP:
•
Cost-effective solution
•
Early warning of critical machine states
•
Continuous fluid monitoring
•
Condition-based maintenance planning
Instructions for use
NOTICE
Impermissible operating conditions
The FMMHP will be destroyed
►
The FMMHP may only be used with mineral oils or raffinates whose basis is
mineral oil.
►
Do not exceed the maximum operating pressure.
Continuously rotatable display
BeWa FMMHP 3386918a en 2009-06-08.doc
2009-06-08
The CS 1000 display can be continuously rotated by
a total of 270°; 180° counterclockwise and 90°
clockwise.
To rotate the display, grasp the cover plate with your
hand and turn in the desired direction.
No tools are required for rotating the display.