230
Model code
FAM – 75 – M – 2 – A – 40 – R – H – C1 – AC1 – 00 – /-V
Basic model
FAM = FluidAqua Mobil
Size
25 ≈ 25 l/min 45 ≈ 45 l/min 60 ≈ 60 l/min
75 ≈ 75 l/min 95 ≈ 95 l/min (50 Hz)
Operating medium
M = Mineral oil - NBR seals, NBR hoses, tested with mineral oil*
I = Insulating oil - NBR seals, NBR hoses,
tested with insulating oil (Shell Diala)**
X = HFD-R fluids - FKM seals, UPE hoses,
tested with HFD-R fluid (Fyrquel)*
B = Biodegradable oils (based on esters) - FKM seals,
NBR hoses, tested with biodegradable oils based on esters*
Mechanical type
1 = Stationary (with feet)
2 = Mobile (with castors and hose attachment)
Voltage, frequency, power supply
A = 400 V, 50 Hz, 3 Ph
F = 230 V, 60 Hz, 3 Ph L = 220 V, 50 Hz, 3 Ph
B = 415 V, 50 Hz, 3 Ph
G = 380 V, 60 Hz, 3 Ph N = 575 V, 60 Hz, 3 Ph1)
C = 200 V, 50 Hz, 3 Ph1) H = 440 V, 60 Hz, 3 Ph1) O = 460 V, 60 Hz, 3 Ph1)
D = 200 V, 60 Hz, 3 Ph1) I = 500 V, 50 Hz, 3 Ph X = other voltages
E = 220 V, 60 Hz, 3 Ph
K = 480 V, 60 Hz, 3 Ph1)
on request
Filter size of fine filter
10 = OLF 10 Toploader (FAM 25/45 only)
26 = OFU 2600 (FAM 60/75/95 only)
40 = MRF 3/11/40 (FAM 60/75/95 only)
Vacuum pump type
R = rotary vane vacuum pump
W = water ring vacuum pump (for FAM 60/75/95 only)
WA = water ring vacuum pump with automatic water supply (for FAM 60/75/95 only)
Heater
H = Heater appropriate for the size (see technical data)
for available voltages, see following pages
Z = without heater
Control concept
C1 = Comfort, control panel language de/en/fr/es/pt/it/nl/da/fi/sv
C2 = Comfort, control panel language de/en/bg/hu/ru/pl/zh
(other languages on request)
Measuring equipment
A = AquaSensor
AC1 = Aqua ContaminationSensor ISO4406:1999
AC2 = Aqua ContaminationSensor SAE AS 4059(D)
AC3 = Aqua ContaminationSensor NAS 1638
Modification number
00 = the latest version is always supplied
Supplementary details
No details = standard
V = FKM seals for
operating fluid
“M” and “I” (if non-standard seal required for the particular
operating fluid
)
(see Model Code under “Operating fluid”) Example : FAM-25-M....-/V
1)
Supplied without plug
* Residues of test fluid will remain in the unit after testing.
** Units not suitable for "Online" and "Onload" operation (transformer in operation and connected to grid).