MRFD2N
Starting up the MRF
Starting up the MRF
The MultiRheo Filter is supplied ex works without any filter elements installed.
Prior to commissioning, insert all filter elements into the filter housing. Proceed as
described on page 26.
Before commissioning, fill and bleed the passive filter housing in each case.
Performing maintenance
WARNING
Hydraulic systems are under pressure
Danger of bodily injury
►
The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
►
Note the tensioning clamp with safety chain of
the air bleed screw.
Use only the air bleed screw with a safety chain
on the tensioning clamp.
This has a safety function and ensures that the
filter housing is vented before the tensioning
clamp is opened.
The MRF is standard equipped with a differential pressure indicator that functions as
a clogging indicator.
Once the contamination retention capacity of the filter elements has been reached,
the clogging indicator responds.
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 25 / 32
MoWa MRFD2 3312153b en-us 2012-08-08.doc
2012-08-08