Unit setup and connection
FAM 10, Instructions, part 1/2
en-US
Page 37 / 72
BEWA FAM10-15 1-2 4170097b en-us 2018-05-23.docx
2018-05-23
Electrical connection of the unit
DANGER
Exposed electrical components in the switch
cabinet
Danger of fatal injury due to electric shock
►
Any work involving the electrical system may
only be done by a properly trained, certified
electrician.
The electrical connection of units without connection plugs to the power
supply module may be performed only by a technician with corresponding
knowledge and skills.
Make sure that the voltage and frequency specifications on the FAM type
label correspond to the existing mains voltage.
If a plug is present on the FAM or if a plug is mounted, then the FAM is to be
operated from a correspondingly fused socket.
The electrical data on the type label of the unit is binding, not that
on the type label of the control cabinet.
Rotating field
Make sure there is a clockwise rotating field. If this is not the case, then the
phases can be rotated in the 16A/32 A connection plug with the aid of the
phase changing switch in the plug. In the 63A version and units without a
connector (60 Hz version), both phases on the terminal block X0 (e.g. L1 and
L2) must be switched.