HNS 3000
Page 16
Version 2014/11/28
HYDAC ELECTRONIC GMBH
Part No. 669927
Settings Display
Setting
Range
Default
settings
Setting the indication range of the fluid level (FLUID LEVEL RANGE)
The fluid level is
indicated in cm
inch/ cm
cm
(dependi
ng on the
model)
The fluid level is
indicated in cm
Setting the level offset (FLUID LEVEL OFFSET) while the fluid level is displayed
The distance between the base of the tank
and the start of the active zone of the fluid
level sensor is considered as the "offset".
Entering this distance will generate a
reference to actual fluid level.
0
Setting the indication range of the temperature (TEMPERATURE RANGE)
The temperature is
displayed in °F
Fahr/ celc
celc
(depending
on the
model)
The temperature is
displayed in °C
Assigning the analogue output (Select Output)*
The analogue output is
assigned to the fluid level
niv/ TEMP niv
Assigns the analogue output to
temperature.
Analogue output (Output)
The analogue output
provides a 4 .. 20 mA signal for
the active measuring range
MAMP/
VOLT/
MAMP
The analogue output
provides a 0 .. 10 V signal for the
active measuring range
Version number (Version)
Displays the current software version.
(view only)
Close the basic settings menu (End)
The basic settings menu
is closed.
YES/ NO
NO
Further changes can be made to
the basic settings.
If any basic settings have been altered, "
ProG
" appears briefly in the display as soon as
the basic settings menu is closed and then the value selected for primary display is
shown.
* This menu point appears only on versions with temperature sensor.