HDA 4800
7
Edition: 2013-06-21
HYDAC
ELECTRONIC
GMBH
Part No.: 669868
E
5 Technical Details
Input data
Measuring ranges (bar)
6;
16;
60;
100;
250; 400;
600
Overload pressures [bar]
15;
32;
120; 200;
500; 800;
1000
Burst pressure [bar]
100; 200;
300; 500;
1000; 2000; 2000
Mechanical connection
G1/4A DIN 3852
Tightening torque
20 Nm
Parts in contact with fluid
Mech. connection: Stainless steel
Seal: FPM
Output data
Signal output, permitted resistance
4 .. 20 mA, 2 conductors
R
Lmax
= (U
B
– 10 V) / 20 mA [k
Ω
]
0 ..10 V, 3-conductor
R
Lmin
= 2 k
Ω
0 .. 20 mA, 3 conductor (source)
R
Lmax
= (U
B
– 7 V) / 20 mA [k
Ω
]
Accuracy to DIN 16086,
Max. setting
≤
± 0.125 % FS typ.
≤
± 0.25 % FS max.
Accuracy at minimum setting
(B.F.S.L.)
≤
± 0.06 % FS typ.
≤
± 0.125 % FS max.
Temperature compensation
zero point
≤
± 0.005 % FS / °C typ.
≤
± 0.01 % FS / °C max.
Temperature compensation
over range
≤
± 0.005 % FS / °C typ.
≤
± 0.01 % FS / °C max.
Non-linearity at max. setting to
DIN 16086
≤
± 0.15 % FS max.
Hysteresis
≤
± 0.1 % FS max.
Repeatability
≤
± 0.05 % FS
Rise time
≤
1 ms
Long term drift
≤
± 0.1 % FS typ. / Jah r
Environmental Conditions
Compensated temperature range 0 ..
-25 .. +85°C
Operating temperature range
1)
-40 .. +85 °C / -25 .. +85°C
Storage temperature range
-40 .. +100 °C
Medium temperature range
1)
-40 .. +100 °C / -25 .. +100 °C
- Marked
EN 61000-6-1 / 2 / 3 /4
- Marked
2)
Certificate No.: E318391
Vibration resistance to
DIN EN 60068-2-6 at 10 ..500 Hz
≤
20 g
Protection class to IEC 60529
IP 65 (connector EN175301-803 (DIN 43650) and
Binder 714 M18)
IP 67 (M12x1 male connector, for use with IP 67
female connector)
Other data
Supply voltage
when applied according to UL specifications
10 .. 30 V DC 2 conductor
12 .. 30 V DC 3 conductor
– limited energy – according to 9.3 UL 61010;
Class 2; UL 1310/1585; LPS UL 60950
Residual ripple of supply voltage
≤
5 %
Current consumption (signal output voltage)
≤
15 mA
Service life
> 10 million cycles, 0 .. 100 % FS
Weight approx.
180
g
Note:
Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are
provided.
FS
(
F
ull
S
cale) = relative to complete measuring range,
B.F.S.L
.=
B
est
F
it
S
traight
L
ine
1)
-25°C with FPM seal, -40°C on request
2)
Environmental conditions according to 1.4.2 UL 61010-1; C22.2 no. 61010-1
Содержание HDA 4800
Страница 14: ...Notizen Notes Notes ...
Страница 28: ...Notizen Notes Notes ...
Страница 42: ...Notizen Notes Notes ...
Страница 43: ...Notizen Notes Notes ...
Страница 44: ...Notizen Notes Notes ...