background image

 

Oil Types

 

 

The HYCON powerpack uses standard hydraulic oil, i.e. all types of mineral oil and 
biodegradable oil, which comply with the following values: 

 
 

Recommended viscosity 

32-68 cSt 

Permitted viscosity 

15-1000 cSt 

Viscosity index 

Min. 100 

Temperature area 

-20° to +70° C

 

-4°F to +160° F  

 

 

Warranty Conditions

 

 

We grant 12 months warranty from the first date of operation – however, not more 

than 18 months from the date of delivery. 
 
The warranty applies to faults that can be related to construction and production 
errors. 

 
Faults caused by incorrect operation, incorrect handling, lack of maintenance or the 
like will not be accepted as warranty. 

 
The warranty covers the parts necessary for repair and the suggested average time 
needed for repair. 

 
For further warranty details, please contact your local dealer. 

 

 

 

HYCON A/S 
Juelstrupparken 11 

DK-9530 Støvring 
Denmark 

 

Martin Møller 
General Manager 

 
02.11.2018

 

 
 

Содержание HPP27VMF

Страница 1: ... HYCON powerpack Please note that the powerpack is delivered without hydraulic oil and therefore it must be filled up with hydraulic oil prior to operation To ensure smooth operation and long lasting performance of your new powerpack we recommend that you study this operating manual carefully and pay special attention to the Safety and Service Precautions We hope you will be satisfied with your ne...

Страница 2: ...s Page Safety precautions 2 Filling up hydraulic oil 2 Technical data 3 Starting instructions 4 Setting of flow 4 Service maintenance and hydraulic settings 5 Oil types 6 Warranty conditions 6 Spare parts list 7 ...

Страница 3: ... of a crane 8 The pressure relief valves are set at 160 bar 2300 psi from our plant Never set them higher 9 Always use filters with by pass The use of filters without by pass may blow the hydraulic hoses and the filter cover Filling Up Hydraulic Oil To fill up with hydraulic oil loosen the filter cover on top of the powerpack Remove the filter element see photo and fill up with oil When oil is sho...

Страница 4: ...nst overheating The powerpack has no POR system and the engine r p m oil flow is adjusted manually by means of the throttle Oil flow connection A 30 l p m 8 g p m at 1900 r p m 40 l p m 10 g p m at 2700 r p m 60 l p m 16 g p m at 3600 r p m Oil flow connections B and C 15 l p m 4 g p m at 1900 r p m 20 l p m 5 g p m at 2700 r p m 30 l p m 8 g p m at 3600 r p m Working pressure nominal 120 bar 1750...

Страница 5: ...has three connections allowing for connection of two tools simultaneously The connections are marked A B and C respectively The oil flow can be adjusted by regulating the engine r p m by means of the throttle Connection A can be set to 30 60 l p m 8 16 g p m Connections B and C can be set to 20 30 l p m 4 8 g p m Connection A cannot be used simultaneously with connections B and C Each connection i...

Страница 6: ...C levers to OFF Then close the valve on the test equipment and adjust the pressure relief valve B according to the technical data Adjust the pressure relief valve by loosening the lock nut and turning the adjustment screw in or out In increases the pressure and out decreases the pressure Retighten the lock nut after adjustment Connect the test equipment to connection C start the powerpack and move...

Страница 7: ... date of operation however not more than 18 months from the date of delivery The warranty applies to faults that can be related to construction and production errors Faults caused by incorrect operation incorrect handling lack of maintenance or the like will not be accepted as warranty The warranty covers the parts necessary for repair and the suggested average time needed for repair For further w...

Отзывы: