![Hyco SP3000HL Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/hyco/sp3000hl/sp3000hl_instruction-manual_2191052008.webp)
Electrical
•
This appliance must be earthed.
•
The electrical connection should be made to the fixed wiring of the property
using the appropriately rated cable (the supply cable must have a minimum
temperature rating of 90°C) and a double pole isolator switch should be used.
•
Please note that an inrush current of several times the steady state current
will
flow for a few hundredths of a second after first switching on, therefore a
slow
blow circuit breaker should be used.
•
PIR devices or other controllers may be used to control this unit provided
all devices are rated to the appropriate electrical loading with due allowance
for the in-rush current. (Hyco Quartz controllers are available and are fitted
with a “soft start” feature that negates the need for a slow blow circuit
breaker).
Cable fitting
•
Remove the back box to gain access to the terminal block.
•
Fit the cable gland into the back box.
•
Feed the cable through the cable gland and secure in the correct position.
•
Connect the cable to the terminal block ensuring the wires are in the
correct terminals:
Brown: L
Blue: N
Green / Yellow:
•
Ensure the connections are tight and there are no loose or frayed wires.
•
Refit the back box.