3. PLUMBING CONNECTIONS
The hot and cold
fi
ttings are at the top of the unit. These connections are colour coded
(blue = cold, red = hot). They are NOT
NOT interchangeable.
All
fi
ttings are provided so connection can be made via 15mm compression
fi
ttings.
Please follow manufacturers instructions provided with the vented tap.
The diagrams below show typical installation with the Hyco Vented mixer tap HFTAPQ
4. ELECTRICAL INSTALLATION
The Electrical Installation must be carried out by a quali
fi
ed electrician in accordance
with the current edition of the I.E.E. Wiring Regulations.
Only connect the heater to a single phase supply with a mains voltage as speci
fi
ed on the
rating plate.
Electrical connection must be made to the
fi
xed wiring of the property by means of
a 13A fused spur. The installation must be
fi
tted with an isolating switch, with a break
contact distance of at least 3mm.
This appliance must be earthed.
The unit is supplied pre-wired. If the cable needs replacing, it must be replaced with a
correctly rated cable and any work should be carried out by a competent person.
DUE TO THE AUTO-RESET FUNCTION OF THE THERMAL CUT-OUT,
THIS APPLIANCE MUST NOT BE USED IN CONJUNCTION WITH A TIMER.
The unit is
fi
tted with an auto-reset thermal cut-out which will operate for safety
reasons in the event of the unit over heating. To reset the thermal cut-out switch
off the power to the unit and allow it to cool down. Ensure the unit is full, and then
switch the unit back on. The thermal cut-out should reset itself.
2
Tighten all connections
to prevent from leaking.