3. PLUMBING CONNECTIONS

The hot and cold 

fi

 ttings are at the top of the unit. These connections are colour coded 

(blue = cold, red = hot). They are NOT

NOT interchangeable.

All 

fi

 ttings are provided so connection can be made via 15mm compression 

fi

 ttings. 

Please follow manufacturers instructions provided with the vented tap.

The diagrams below show typical installation with the Hyco Vented mixer tap HFTAPQ

4. ELECTRICAL INSTALLATION

The Electrical Installation must be carried out by a quali

fi

 ed electrician in accordance 

with the current edition of the I.E.E. Wiring Regulations.

Only connect the heater to a single phase supply with a mains voltage as speci

fi

 ed on the 

rating plate.

Electrical connection must be made to the 

fi

 xed wiring of the property by means of 

a 13A fused spur. The installation must be 

fi

 tted with an isolating switch, with a break 

contact distance of at least 3mm. 

This appliance must be earthed.

The unit is supplied pre-wired. If the cable needs replacing, it must be replaced with a 
correctly rated cable and any work should be carried out by a competent person.

 

DUE TO THE AUTO-RESET  FUNCTION  OF THE THERMAL  CUT-OUT, 

 

THIS APPLIANCE MUST NOT BE USED IN CONJUNCTION WITH A TIMER.

 

The unit is 

fi

 tted with an auto-reset thermal cut-out which will operate for safety

 

reasons in the event of the unit over heating. To reset the thermal cut-out switch 

 

off the power to the unit and allow it to cool down. Ensure the unit is full, and then 

 

switch the unit back on. The thermal cut-out should reset itself. 

2

Tighten all connections 
to prevent from leaking.