The Shelter EPA-Approved Furnace has been engineered to accommodate the heating requirements of the average sized 

home, even during winter’s coldest months.  It is constructed with high grade, heavy gauge steel and is continuously welded 

to assure the highest structural strength.  In addition, the firebox is lined with insulated stainless steel panels to ensure many 

years of energy efficient service. The design of the secondary combustion chamber increases fuel efficiency by creating a 

“secondary burn” of smoke and wood gases before they are vented up the chimney. The cast iron doors are custom fitted to 

provide an airtight seal, greatly extending the burn time and ensuring maximum efficiency in fuel consumption.  The heavy-

gauge cast iron grate, designed for maximum heat transfer, allows for convenient ash removal and reduced maintenance.
For total comfort and convenience, a thermostatically controlled draft and circulation blower system is included.  These fully 

automatic components furnish rapid heat disbursement throughout your home, minimizing recovery time when the wall 

thermostat demands heat.
All of these features are standard, offering you the most efficient, durable and affordable indoor wood burning furnace.
Efficiency was determined using the higher heating value of the fuel per B415.1-10 testing requirements. Dry seasoned wood 

will develop greater BTU output. A well-insulated dwelling will always lead to better results and overall improved fuel usage 

efficiency.
Your Shelter Furnace is designed to be either a supplemental or central heating source for your home.  This wood burning 

furnace may be installed in parallel with a properly operating electric, gas or oil-fired central furnace, listed or certified in 

accordance with a nationally recognized safety standard, and within clearances specified on the nameplate.  When in a 

parallel installation the static pressure of the central furnace plenum may not exceed 0.15 water column inches and the 

maximum setting on central furnace limit switch is 182°F.  With the Shelter Furnace in an “Interconnection Arrangement” your 

furnace should be upstream of the central furnace.  The Shelter Furnace warm air supply should never be connected to return 

air for the central furnace.  A qualified installer should perform the installation.

 

This wood heater needs periodic inspection and 

repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating 

instructions in this manual.

IMPORTANT:  FOR TECHNICAL SUPPORT OR CUSTOMER SERVICE 

ISSUES, DO NOT RETURN TO THE STORE (THE STORE DOES NOT 

HAVE 

REPLACEMENT PARTS), CALL 1-800-875-4788.
Forced Hot Air Circulation:

The plenum size of your Shelter Furnace must not be reduced to less than 100 square inches, and must provide a minimum 

of 18 inches between the top of your Shelter Furnace and the main trunk connection.  The plenum attached to the furnace 

must be constructed of metal.  The warm air supply duct system should be constructed of materials with a minimum 

temperature rating of 250° Fahrenheit.

Clearances:

Unit must be placed on a non-combustible floor.  This floor must extend at least 16 inches in front, 8 inches on either side of 

fuel loading and ash removal doors, underneath the chimney connector and must extend 2 inches on either side of the 

chimney connector.  The furnace must maintain the following clearances to combustibles:

• Heat plenum = 2 inches
• Chimney connector = 18 inches
• Front = 48 inches
• Rear = 12 inches
• Sides = 6 inches
• Main furnace = 12 inches

These are minimum clearances and should be strictly followed.  In the case of a power outage, a dangerous level of heat 

accumulation may develop.  Do not store fuel or other combustible materials within installation clearances.

3

Содержание Shelter Furnace SF1000

Страница 1: ...G INDOOR FURNACE MODEL SF1000 Manufactured by Shelter Furnace 10950 Linpage Place Saint Louis MO 63132 1 800 875 4788 MADE IN USA Revision II June 2017 Certified to UL391 Sept 2010 CSA B366 1 2014 Con...

Страница 2: ...This Page Intentionally Blank...

Страница 3: ...ut Wood that is properly cut and stored to dry will produce more BTUs and higher heat output than wood that has a higher moisture content Wood with higher moisture content will create creosote in the...

Страница 4: ...ve in perfect condition Any visible damage should be noted on the freight bill at the time of delivery If upon unpacking your Shelter Furnace you find damage has occurred during transit notify your su...

Страница 5: ...12 14 14 14 15 15 15 15 15 Furnace Diagram with Parts List 17 Blower Motor Assembly Diagram 18 Wiring Diagram 19 Troubleshooting 20 Warranty Information 25 DOUBLE CHECK TO MAKE SURE YOU HAVE RECEIVED...

Страница 6: ...cognized safety standard and within clearances specified on the nameplate When in a parallel installation the static pressure of the central furnace plenum may not exceed 0 15 water column inches and...

Страница 7: ...coming off the top of the appliance can only go up or horizontal to connect into the main supply duct Never run the plenum down as this will create a heat buildup in the furnace causing the blower to...

Страница 8: ...your convenience your Shelter Furnace has been factory assembled and the electrical control assembly pre wired 1 Fasten the right and left side angle brackets to the circulation blower using 4 20 bolt...

Страница 9: ...ke sure the filter box is tightly pressed to the back of the furnace Use 4 1 4 bolts included to firmly attach the filter box to sides of furnace Filter Box 1 4 Bolts Panel A Panel B Panel C Panel A 8...

Страница 10: ...should point toward the furnace to form drip free connections thereby reducing the possibility of creosote leakage from the joints Installing a non UL listed heat reclaimer in the pipe is not recomme...

Страница 11: ...discharge When using a brick chimney you must line the entire chimney with stainless steel liner The liner must be 6 for the SF1000 The diameter of the chimney stack should be consistent throughout th...

Страница 12: ...gether The return air system should be a minimum of 10 larger than the heat outlet to readily transfer the cold air back to the furnace Avoid using 90 elbows in duct runs 45 elbows provide better airf...

Страница 13: ...t Firewood should be stacked to provide a free flow of air between the logs thus allowing more rapid seasoning of the wood If wood is stored outdoors it should be completely covered year round to prot...

Страница 14: ...on of these substances may release harmful toxic gases Do Not Burn Garbage Lawn clippings or yard waste Materials containing rubber including tires Materials containing plastic Waste petroleum product...

Страница 15: ...firing your furnace This type of occurrence is usually symptomatic of heat demands in excess of furnace capacity Contact an authorized professional to determine if your Shelter Furnace has been improp...

Страница 16: ...With the cover closed no air is introduced into the firebox then the fire dies preventing the furnace from possible overheating and damage Creosote Formation and Need for Removal When wood is burned...

Страница 17: ...d will produce a higher BTU output and a longer burn time Refer to the nameplate on furnace for additional information WARNING RISK OF FIRE Do not operate with the flue draft exceeding 08 water column...

Страница 18: ...SEMBLY FCE FDA 3 1 FURNACE SHELL FC10SHELL 4 2 SIDE PANEL ASSEMBLY FCE 10SP 5 1 BLOWER ASSEMBLY FC3SPMOTOR 5a 1 BLOWER MOTOR FCDD037P 5b 1 BLOWER HOUSING FCBH 6 1 FILTER BOX BOTTOM WAF FBB 7 2 FILTER...

Страница 19: ...ram PARTS LIST DESCRIPTION QTY ITEM BLOWER WHEEL 1 1 BLOWER HOUSING 1 2 MOTOR CAPACITOR 1 3 BLOWER MOTOR 1 4 2 1 2 3 PARTS LIST DESCRIPTION QTY ITEM BLOWER WHEEL 1 1 BLOWER HOUSING 1 2 MOTOR CAPACITOR...

Страница 20: ...A B B FAN LIMIT CONTROL WALL THERMOSTAT 120V AC 24V AC TRANSFORMER RELAY DRAFT BLOWER MOTOR BLOWER MOTOR 120V AC POWER SUPPLY WHITE BLACK GREEN BLACK WHITE RED RED RED YELLOW BLACK ORANGE WIRING DIAGR...

Страница 21: ...r vibrates during operation Screw on squirrel cage is not tight Check squirrel cage alignment and position so that it does not drag on the housing during rotation then tighten the screw sufficiently t...

Страница 22: ...rn air duct system Install filter box on furnace Install filter in filter box Filter box not installed or no filter in filter box 5 Problem Smoke from the fire chamber is puffing back through the forc...

Страница 23: ...nstall flue gas thermometer and maintain stack temperatures between 300 and 400 F See 9 Insufficient chimney draft 8 Improper connection in stove pipe causing air leakage or a structural defect in the...

Страница 24: ...truction outside chimney such as a tree Flue is located too close to the peak of the roof or does not rise above it to provide the proper draft Backdraft damper is in the closed position 9 Problem Odo...

Страница 25: ...of insect infestation such as burrows or holes avoid using if possible Do not store wood indoors Possible Causes Remedies 13 Problem Circulation blower will not turn on Defective fan limit control Che...

Страница 26: ...This Page Intentionally Blank 23...

Страница 27: ...ick and door gaskets are excluded from this warranty In order to exercise the aforementioned warranty a certified professional must determine the appliance part to be defective He or she must submit a...

Страница 28: ...This Page Intentionally Blank...

Отзывы: