Installation Condition
Require 220v AC power. GSM signal can cover the area where the terminal is placed.
Signal quality affects voice quality direct.
The installation for connecting to ordinary telephone direct
1.
Install the SIM card proceeding as “Installing the SIM Card”
2.
Connect one end of the telephone line to “Telephone port” and the other end connect
to a telephone.
3.
Install the antenna and power supply well. The distance between telephone and
terminal is 1.5m at least.
4.
Connect one end of the power adapter to “Power port” and another end connect to
220v AC power. About 10-45 seconds later, the terminal works in gear (The login
time is different according to local network).
Draw your attentions:
Because there are many types of ordinary telephone and their
electric parameters are different.In order to avoid mutual disturbance between telephone
and terminal and affects voice quality.The distance between telephone and terminal must be
beyond 2m.
The installation for connecting to register cost equipment
If users demand register cost during calls, register cost equipment can be connected
between terminal and ordinary telephone. Register cost equipment registers cost according
to anti-polarity signal that is provided by terminal
Operating the terminal
The Information of Signal Quality and Software Version
If the connected telephone has the function of displaying incoming calls, the
telephone rings after it is in login onto GSM network successfully and a code of 8 digits will
be displayed. The code indicates the information of signal quality, malfunctions and software
version as follows:
- The first two digits indicate the signal quality, it ranges from “00” to “31”. Stronger the
signal is, bigger the digits is. If it is less than 10, the quality of voice will be poor.
- The third and the forth digit is the code of malfunction:“00”: good “11”: failed in login
onto GSM network “22” or “33”: PIN error (PIN code isn’t 1234 or PIN code isn’t disabled)
“44”: lock card error “55”: lock terminal error,“77”: lock network error, “99”: read SIM
card error)
- The later four digits is software version code: for example 4060 indicates the software
version code is 4.06.
If the telephone displays “11”, “22”, “33”, “44”, “77”, “99” and it can’t work in gear,
please contact the service provider.