background image

7A

1).

6. 3 pin XLR connectors are more popular than 5 pin XLR.

3 pin XLR: Pin1: GND, Pin2: Negative signal (-), Pin3: Positive signal (+)
5 pin XLR: Pin1: GND, Pin2: Negative signal (-), Pin3: Positive signal (+)

Pin4/5: Not Used.

8. Troubleshooting

Following are a few common problems that may occur during operation. Here are some

suggestions for easy troubleshooting:

A. The fixture does not work, no light

1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.

B. Not responding to DMX controller

1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2. If the DMX LED is on and no response to the channel, check the address settings and

DMX polarity.

3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB

of the fixture or the previous one.

4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that may

cause damage or interference to DMX interface circuit.

C. Some fixtures don’t respond to the easy controller

1. You may have a break in the DMX cabling. Check the LED for the response of the

master/ slave mode signal.

2. Wrong DMX address in the fixture. Set the proper address.

D. No response to the sound

1. Make sure the fixture does not receive DMX signal.
2. Check microphone to see if it is good by tapping the microphone.

9. Fixture Cleaning

The cleaning of internal must be carried out periodically to optimize light output. Cleaning

Содержание HSF 5.4

Страница 1: ...User Manual Please read the instructions carefully before use ...

Страница 2: ... OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to set the unit 5 How to control the fixture 6 DMX512 Configuration 7 DMX512 Connections 8 Trouble shooting 9 Fixture Cleaning ...

Страница 3: ...using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and there might be a hazard of electric shock To prevent or reduc...

Страница 4: ...e operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by ...

Страница 5: ...turn to the original mode 4 2 Main Function Chart 5 How to control the fixture 1 Black Out Turn on off 2 Auto Auto show 3 Sound Sound active 4 Strobe Only JUMP and Static color mode The corresponding button is 0 9 this button has effectivity 5 Fade JUMP Gradual change mode Jump change mode switch 6 Sensitivity sound sensitivity adjust 7 R Red dimmer in the dimming mode 8 G Green dimmer in the dimm...

Страница 6: ... G B W A UV Gradual change speed adjust jump change speed adjust 16 0 Function switch Dimming mode and monochromatic mode 6 DMX512 Configuration 6 channels Mode Channel Value Function CH1 0 255 RED dimmer CH2 0 255 GREEN dimmer CH3 0 255 BLUE dimmer CH4 0 255 WHITE dimmer CH5 0 255 Amber Yellow dimmer CH6 0 255 Purple UV dimmer 10 channels Mode Channel Value Function CH1 0 255 Master dimmer CH2 0 ...

Страница 7: ...annot be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 4 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 oh...

Страница 8: ...to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy cont...

Страница 9: ...r particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Отзывы: