HOW TO CONTROL THE FIXTURE

There are two ways to control the fixture
A. Universal DMX controller
B. Master/Slave operation

A. Universal controller

The fixture can be set the DMX address remotely by universal DMX controller. 

First, you need to programming two scenes into a chase, and then link the 

fixtures to the universal DMX controller. When you run the chase, all the 

fixtures of the chain will be set the series DMX address automatically.  

The fixture uses four channels. Please refer to the following diagram to set 

the address for the first four units.

B. Master/Slave operation

The fixture will allow you to link 16 fixtures together and operate without a 

controller. In Master/Slave mode, the first fixture will control the others to 

give an automatic, sound activated, synchronized light show. This function 

is good when you want an instant show. The first fixture it’s DMX input cable 

will have nothing connect it, and the other fixtures will be set in slave mode 

automatically. Their DMX input cables connect the last fixture DMX output 

cable (daisy chain). Any fixture can act as a Master or as a Slave

OR

001

012

023

034

001

014

027

040

Содержание HMHSPOT40

Страница 1: ...USER MANUAL 40 WATT LED SPOT HMHSPOT40 ...

Страница 2: ......

Страница 3: ...ect main power before servicing and maintenance Use safety chain when fixes this fixture Don t handle the fixture by taking its head only but always by taking its base Maximum ambient temperature is Ta 40 c Don t operate it where the temperature is higher than this In the event of serious operating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carri...

Страница 4: ...X channels Pan 540degree Tilt 270degree 4 Operational Modes DMX Master Slave auto sound activated Gobo wheel 11 static gobos sharking open Color wheel 9 fixed colors White Light Source 1x40W White LED Power supply 100 240Vac 50 60Hz Power consumption 65 W Packing Size L375 W260 H305mm Weight 5 65k CAUTION There are no user serviceable parts inside the fixture Do not open the housing or attempt any...

Страница 5: ...secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it 1 MENU 2 UP 3 DOWN 4 ENTER To select the program function Increase param...

Страница 6: ... 60S LCD Display Off after 60s no operate SundHig 0 16 Sound sensitive MotorST ColrREV 0 255 GoboREV 0 255 PrimREV 0 255 FousREV 0 255 PanREV 0 255 TiltREV 0 255 Xreverse NO Pan Forward YES Pan Reverse Yreverse NO Tilt Forward YES Tilt Reverse Xyfbstin NO XYOptical Coupling Closed YES XYOptical Coupling Open Info Version Software Version Runtime Units hours Rest NO YES Reset MAIN FUNCTION CHART ...

Страница 7: ...e fixture uses four channels Please refer to the following diagram to set the address for the first four units B Master Slave operation The fixture will allow you to link 16 fixtures together and operate without a controller In Master Slave mode the first fixture will control the others to give an automatic sound activated synchronized light show This function is good when you want an instant show...

Страница 8: ...3 No Strobe 64 123 Random Strobe effect from slow to fast 124 127 No Strobe 128 191 Pulse Strobe effect from slow to fast 192 195 No Strobe 196 253 Random Pulse Strobe effect from slow to fast 254 255 No Strobe 6 8 0 127 Continual positioning 128 130 Colour half 131 133 Color 1 134 136 Colour half 137 139 Color 2 140 142 Colour half 143 145 Colour 3 146 148 Colour half 149 151 Colour 4 152 154 Col...

Страница 9: ...lor 9 182 184 Colour half 185 187 Color 10 188 194 Open 195 219 Forwards rainbow effect from fast to slow 220 224 No rotation White 225 249 Backwards rainbow effect from slow to fast 250 255 Colour marcos 7 9 0 4 Open 5 9 Gobo 1 10 14 Gobo 2 15 19 Gobo 3 20 24 Gobo 4 25 29 Gobo 5 30 34 Gobo 6 35 39 Gobo 7 40 44 Gobo 8 45 49 Gobo 9 50 54 Gobo 10 55 59 Gobo 11 60 64 Open 65 74 Gobo 1 Shake ...

Страница 10: ...ation Stop 215 239 Backwards gobo wheel rotation from slow to fast 240 255 Gobo Marcos 8 10 0 15 Open 16 127 Prism indexing 128 255 Prism 2 9 11 0 255 Focus Continuous adjustment from far to near 10 Macro function 12 0 19 Custom Control by CH1 CH9 20 99 Auto all of other CH invalid 100 199 Sound all of other CH invalid 200 255 Custom Control by CH1 CH9 11 13 0 199 Custom Control by CH1 CH9 200 255...

Страница 11: ...MX circuit when one of the units power is disconnected 4 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 5 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number ...

Страница 12: ...s and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller 1 You may have a break in the DMX...

Страница 13: ...frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days ...

Страница 14: ......

Страница 15: ......

Страница 16: ...www vivaafrika co za ...

Отзывы: