Installation and Maintenance Manual
18
Wiring Control Inputs to the Smart Touch Controller for HTG
1. Test the basic open and close operator function before wiring the external control inputs. This
makes it easier to troubleshoot if an unexpected function issue arises.
2. Each input has an LED to indicate when that input is active. To disclose the input status, the LED
tact button must be pushed. This button is in corner near the Stop input.
3. All the control device inputs listed below are shown as a single wire input because the other wire
is connected the Common Terminal Buss on the Power Supply board. The Emergency Close
and Fire Dept. Open inputs are an exception and require a +24 Volt input in order to be activated.
The +24 is available at the spade terminals next to the Common Buss.
Smart Touch Controller Inputs
1)
*
Stop Push button
(N.C. input, jumper to Common if unused)
2)
*
Open Push Button
(not for radio or remote access controls)
3)
*
Close Push button
(not for radio or remote access controls)
4) Remote Open & Radio Control
(For radio / remote open device -
menu opt. to also close the gate, but only
when fully open)
5) Open/Close button
(pushbutton or radio controls)
6) Partial Open
(this input disabled on barrier arm gates)
7) Open interlock input or Time clock Open
(menu configurable)
8) Free Exit vehicle detector
9) Disable Free Exit vehicle detector
10) Inside Obstruction vehicle detector
(Inside reversing loop)
11) Outside Obstruction vehicle detector
(Outside reversing loop)
12) Reset vehicle detector
(Closing loop under arm)
13) Edge Sensor
(14-15) Photo eye Common Power
(supply for PE power & PE Com)
(17) Photo eye Open direction
(input
not used in barrier arm gates)
(19) Photo eye Close direction
(beam to be under the barrier arm)
(21) Charger AC power loss
(only used in battery type operators)
(22) Spare Input
(unused – may have function in custom applications)
(23)
*
Emergency Close
(must menu enable and input +24 Volts to
trigger) Overrides photo eyes, gate edge & vehicle detectors.
(24)
*
Fire Dept. Open
(must menu enable and input +24 Volts to
trigger) Overrides photo eyes & gate edge.
*
Do not connect an external control to terminals #1, 2 or 3,
unless the controls are located such that there is a clear view
of the entire gate area. For controls not within sight, use input
terminals #4, 5 or 7.
*
The Emergency Close and Fire Dept. Open inputs are to be used only if
access to these controls are guarded in sufficient manner such that there is
always supervision when activated.
Содержание HTG 320-2
Страница 16: ...Installation and Maintenance Manual 10 Components of the Barrier Arm Gate Operator ...
Страница 19: ...Installation and Maintenance Manual 13 ...
Страница 20: ...Installation and Maintenance Manual 14 ...
Страница 21: ...Installation and Maintenance Manual 15 ...
Страница 25: ...Installation and Maintenance Manual 19 ...
Страница 41: ...Installation and Maintenance Manual 35 E95 ...
Страница 54: ...Installation and Maintenance Manual 48 ...
Страница 55: ...Installation and Maintenance Manual 49 ...
Страница 57: ...Installation and Maintenance Manual 51 ...
Страница 58: ...Installation and Maintenance Manual 52 Parts Breakout ...
Страница 59: ...Installation and Maintenance Manual 53 Parts Breakout ...
Страница 60: ...Installation and Maintenance Manual 54 Parts Breakout ...
Страница 61: ...Installation and Maintenance Manual 55 Parts Breakout ...
Страница 62: ...Installation and Maintenance Manual 56 Parts Breakout ...
Страница 63: ...Installation and Maintenance Manual 57 Parts Breakout ...
Страница 64: ...Installation and Maintenance Manual 58 Parts Breakout DC Power Supply Battery Pack Components ...