SECTION 5 | WIRING DIAGRAMS
SECTION 5 | WIRING DIAGRAMS
2 3
9
8
7
4 5 6
1
10 11 12
13 14 15
CONNECTOR A
2 3
9
8
7
4 5 6
1
10 11 12
CONNECTOR B
2 3
9
8
7
4 5 6
1
CONNECTOR C,H
2 3
1
CONNECTOR D
1
3
2
4
5
6
7
8
9
10
11
12
13
14
CONNECTOR J
BATTERY
CHARGER
UPR CTL
SEE
WD-112-21-404-51
J
14
13
7 8
12
9 10 11
5
3
6
4
2
1
ACTUATOR
TS-100
M2+
M2-
B-
M1-
M1+
B+
B C
2
6
8 9
4
3
7
5
1
H
7
6
8
9
14
13
12
10
11
15
A
3
1
5
2
4
FLASHING
AMBER
BEACON
BUTT-?
1
2
DRIVE
M
M2+: L MOTOR (YEL)
M2-: L MOTOR (YEL-STR)
T-8: L-BRAKE (BLK)
T-5: L-BRAKE (RED)
M1+ : R MOTOR (ORG)
T-8: R-BRAKE (BLK)
M1- : R MOTOR (ORG-STR)
T-5: R-BRAKE (RED)
BRAKE
BRAKE
M
DRIVE
M2+: L MOTOR (YEL)
M2-: L MOTOR (YEL-STR)
M1-: R MOTOR (ORG)
M1+: R MOTOR (ORG-STR)
2
1
BUTT-1
NO
NC
D
1
3
2
AS1
+
-
DOWN
UP
-
+
PUMP
RESERVOIR
+
-
HYD PUMP M
T-5: R-BRAKE (RED)
T-5: L-BRAKE (RED)
T-8: L-BRAKE (BLK)
T-8: R-BRAKE (BLK)
+
-
V
4
3
2
1
+
-
8
6
2
3
7
1
5
4
LWR CTL
WD-112-21-405-50
1
2
BATTERY
BATTERY
112-21-407-50
112-21-314-50
BEACON LIGHT,IF SO EQUIPPED
112-01-320-50
1002101650
ELEC-117-DC-1
ELEC-641C
ELEC-641E
ELEC-641A
112-21-304-50
112-21-420-50
112-21-425-50
CHR INTERLOCK, IF SO EQUIPPED
JUMPER IF NOT EQUIPPED
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
B-SIZE
ORIGINALLY DRAWN BY:
Custom Equipment, LLC
Richfield, WI 53076
Phone: (262)644-1300
DATE:
WD,PRO SERIES,S4
SCALE:1:4
DO NOT SCALE DRAWING
THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY TO CUSTOM EQUIPMENT AND IS LOANED IN EXPECTATION THAT IT WILL BE KEPT CONFIDENTIAL AND USED ONLY FOR THE PURPOSE FOR WHICH IT IS LOANED.
SPEC/MATL: Schematic
DRAWING #: WD-112-20-401-50
REV
DESCRIPTION OF CHANGE
DATE REV BY
D
CHANGED MAIN WIRE HARNESS
05/31/2019
DJS
ECO #
2019-3296
SHEET 1 OF 5
WEIGHT: APPROX. 0.00 LB.
D
5.1 | WIRING DIAGRAM
Part No. WD-112-20-401-50
MAINTENANCE & TROUBLESHOOTING
PS-1030 | PS-1430
SUPO-742
REV A
MAINTENANCE & TROUBLESHOOTING
PS-1030 | PS-1430
SUPO-742
REV A
22