![HWH 680 Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/hwh/680-series/680-series_operators-manual_2190616008.webp)
LEVEL FLOOR ROOM EXTEND PROCEDURES
OPERATING PROCEDURES
fully extended the sub floor will raise into position. The pump
running, the red PUMP ON light will be on. When the room is
SWITCH in the "EXTEND" position. When the pump is
can now be extended.
turned on, the AIR SEAL indicator light will come on. The room
3. Approximately twenty seconds after the KEY SWITCH is
the AIR SEAL light comes on, the room will not extend.
4. To extend the room, press and hold the ROOM CONTROL
the room air seal to deflate.
SWITCH and turn the key to the "ON" position. This will allow
2. Insert the key in the ROOM OPERATOR’S PANEL KEY
NOTE: If the ROOM CONTROL SWITCH is pushed before
room locks will not disengage.
locks in place. Do NOT attempt to force the room out if the
locking cylinders. The room can NOT be extended with the
1. Turn the vehicle ignition to the "ON" position.
OBSTRUCTIONS BEFORE EXTENDING OR RETRACTING THE
THE SURROUNDING AREAS ARE CLEAR OF PEOPLE AND OTHER
SION, THE MOVING SECTIONS OF THE FLOOR SYSTEM AND
TO ENSURE THAT ALL MOVING PARTS OF THE ROOM EXTEN-
the vehicle to fully extend the room.
IMPORTANT: This room is equipped with hydraulic room
NOTE: Make sure there is adequate clearance outside of
if the coach is not level.
ROOM.
CAUTION:
be extended.
NOTE: The park brake must be set before the room can
IMPORTANT: It is not recommended to extend the room
IT IS THE OPERATOR’S RESPONSIBILITY
CONTROL SWITCH can be released after the pump shuts
6. Remove the KEY to prevent undesired operation of the room.
5. Turn the KEY SWITCH to the "OFF" position. The room air
ROOM EXTENSION SYSTEM CALL HWH CORPORATION,
7. Turn the ignition switch off.
1-800-321-3494, CUSTOMER SERVICE, FOR ASSISTANCE.
IMPORTANT: IN THE EVENT OF ANY FAILURE OF THE
seal will inflate.
off.
When the room is fully extended, the sub floor will then raise
extended. Release the switch after the pump has shut off.
will automatically shut off when the room and floor are fully
into position. The procedure is ended automatically. The ROOM
after the KEY SWITCH is turned on, the AIR SEAL INDICATOR
turned on, the air seal will deflate. Approximately 20 seconds
release the switch immediately. Never attempt to force
the room locks will disengage and the room will begin to extend.
When the ROOM CONTROL SWITCH is pushed to "EXTEND"
When the KEY SWITCH is
LIGHT will come on.
is in the "ON" position the room air seal will deflate.
ROOM AND FLOOR OPERATION:
the operation of the room.
NOTE: Anytime the KEY SWITCH is on and the ignition
IMPORTANT: If either side of the room stops moving,
NOTE: Releasing the ROOM CONTROL SWITCH will halt
the system.
IMPORTANT: If the room is fully extended and the
Pump On light stays on for more than 30 seconds,
release the ROOM CONTROL SWITCH.
07OCT03
MP35.4753
Содержание 680 Series
Страница 40: ......