Insert function
No.
Item
Factory set
Instruction
1.
Pe
n
et
ra
ti
o
n
s
et o
n
DCE
P
1
(
on
)
1 gear
Step 1: press “parameter selection” for 5s, come into insert function set mode,
voltmeter show “00.”
Step 2: adjust “parameter adjust” make ammeter show “2”, press
“characteristic select”, come into DCEP penetration setting
Step 3: voltmeter show “0”, turn “parameter adjust”, press “pole selection”
when ammeter show “0”, to turn off the penetration adjust t and exit from the
insert function set. Press “pole selection” when ammeter show “1”, to start the
penetration set
Step 4: voltmeter show “1”, turn “parameter adjust”, penetration have 4 gear
select(1
st
gear the penetration is lightest, the 4
th
gear penetration is deepest),
press “pole select” to storage then exit.
2.
U
p
/d
o
w
n
s
lo
p
e ad
ju
st f
o
r
A
C c
u
rr
en
t e
xc
h
an
ge
0
(
off
)
Step 1: press “parameter selection” for 5s, come into insert function set mode,
voltmeter show “00.”
Step 2: adjust “parameter adjust” make ammeter show “3”, press
“characteristic select”, come into AC current up/down slope adjust setting
Step 3: voltmeter show “0”, turn “parameter adjust”, press “pole selection”
when ammeter show “0”, to turn off the slope adjust and exit from the insert
function set. Press “pole selection” when ammeter show “1”, to start the slope
control
Step 4: voltmeter show “1”, turn “parameter adjust”, adjust AC up/down slope
(1
~
100
(
A/100
μs
)
)press “pole select” storage ,the value is 10
Step 5: voltmeter show “2”, up slope and down slope value set same, press
“pole select” to storage, then exit.