Title
Rev.
Page
HPP-240
Ver1.0
P.9
2-3)
HEX Dump Print
Turn on the power after placing the Dip SW1 number 8 to ON position. After printing as
[HEX DUMP MODE], it will print all receiving datas to 16 hexadecimal data for all
receiving datas. This would be useful when developing an application because this
notifies the transmission status.
Prints if 12 digits is received.
Data under 12 digits will print when you press the feed button.
Control Code (Below 1F
16
) prints as “.”
Prints as “^” when 80
16
or above.
[Print Sample]
16 hexadecimal indicator ASCII indicator
[HEX DUMP MODE]
41 42 43 44 45 46 47 47 49 A B C D E F G H I
30 31 32 33 34 35 36 37 38 0 1 2 3 4 5 6 7 8
FF 1B 69 ^ . i