![Hwasung HMC-060 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/hwasung/hmc-060/hmc-060_technical-manual_2190553022.webp)
Title
Rev.
Page
HMC-060, HMK-060 Release 2
Ver2.0
P.21
FF
[Name]
Print and return to standard mode in page mode
[Format]
ASCII
FF
Hex
0Ch
Decimal
12
[Range] -
[Descript]
Print the data in the print buffer and returns to standard mode
[Caution]
Use ESC+FF once standard mode not to return
SUB+’x’+n
[Name]
Extension Graphic Mode, Korean Mode
[Format]
ASCII
SUB
x
n
Hex
1A
78h
n
Decimal
26
120
n
[Range] 0≤n≤1
[Initial Value] n=0
[Descript]
n=0 : Korean Mode, First code is A1h more, automatically transfer Korean in 2 bytes
n=1 : Extension Graphic Mode, Every code is setting in 1 byte
Extension Graphic font will be printed
SUB+’p’+n
[Name]
Off line printing according to the paper detection
[Format]
ASCII
SUB
p
n
Hex
1A
70h
n
Decimal
26
112
n
[Range] 0≤n≤1
[Initial Value] n=1
[Descript]
n=0 : Not transition to offline once paper empty (data communication available)
n=1 : Transition to offline once paper empty (data communication not avaiable)
SUB+’b’+n
[Name]
Black mark detection
[Format]
ASCII
SUB
b
n
Hex
1A
62h
n
Decimal
26
98
n
[Range] 0≤n≤3
[Descript]
n=0 : the feeding in easy flow direction till black mark is out
n=1 : the feeding in easy flow direction till black mark is detected
n=2 : the feeding in reverse direction till black mark is out
n=3 : the feeding in reverse directoin till black mark is detected
[Caution]
the feeding range is restricted in 30Cm
Once the detection distance is over in 30Cm, it could be jammed