12
13
Cleanion Solutions
Troubleshooting Guide
Acidic water-based solutions : remove rust, tarnish or scale.
Alkaline water-based solutions :
Mild :
Light oils, greases, cutting oils, coolant compounds.
Mild to strong :
Heavy greases and oil, waxes, vegetable oils, inks, milk residues.
Heavy-duty :
Mill scale, heat-treat scale, corrosion or oxides.
If your cleaner does not operate satisfactorily, please check the tables below for possible causes before calling your
service center.
Problem
Cause
Solution
Unit doesn
’
t start
1. Unit not plugged in properly
2. Power button not on
3. Faulty start button
4. Faulty fuse
1. Plug into electrical outlet
2. Press power button on
3. Call nearest service center
4. Replace new fuse
(located on back of the unit/
fuse box)
Unit operates but
does not heat solution
Faulty heater elements
Call nearest service center
Unit operates but
time/temp display
does not function
Faulty time/temp elements
Call nearest service center
Decreased
ultrasonic activity
1. Solution is spent or dirty
2. Solution level is too low
3. Liquid level is incorrect for
load
4. Bath bottom is covered with
soil particles
5. Solution is not degassed
1. Change solution
2. Add more solution
3. Adjust level with load until
activity increase
4. Clean bath with warm water
and wipe with a nonabra-
sive cloth
5. Make sure that bath was
filled with water and has run
5 minutes
Clogged drain
Clogged drain or hose
Call nearest service center
Содержание POWERSONIC 605
Страница 1: ...Model POWERSONIC 605 610 620 HWASHIN ULTRASONIC CLEANER INSTRUCTION MANUAL ...
Страница 15: ......