HWAM I 30/65 Скачать руководство пользователя страница 7

Page 7 of 20 pages

I

nstallatIon

 

manual

 

n general

Congratulations on your new HWAM insert. We are pleased that you have chosen a HWAM insert and 
confident that it will give you much pleasure. To ensure optimum operation and safety, we recommend 
that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by 
the retailer. For an overview of HWAM retailer, visit www.hwam.com under “Retailer locations”.

Safety

The installation of your HWAM insert must always comply with all European, national and local building 
regulations. The installation must be carried out in accordance with the instructions in the installation 
and user manuals and subsequently registered with the local authorities. Upon installation, the chimney 
sweep must approve the installation before you can start using the insert. All HWAM insert packaging 
material must be handled in accordance with local waste management regulations.

Room requirements

Always ensure a supply of fresh combustion air to the room where the insert is to be installed. The insert 
uses approx. 16-37 m

3

 of air per hour (depending on the setting of the air control lever). A window that 

can be opened or an adjustable air valve will be sufficient. It must not be possible to block the adjustable 
air valve/grate. In newly built/airtight dwellings, we recommend that a fresh air system should be installed 
for the direct supply of external air to the combustion. This fresh-air system may be bought separately.

Before installing the insert, make sure that the floor can carry the insert, the chimney and any other 
parts required for the installation.

Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes 
be treated as a combustible wall, in which case we ask you to contact your local chimney sweep or glass 
producer to hear at what distance the insert should be kept from glass.

Technical measures and data

Test results from nominal test EN 13240

Nominal heating effect

10.0 kW

Flue gas temperature EN 13240 measurement point

302ºC

Flue gas temperature measured in the outlet socket

350ºC

Exhaust gas flow

9.07 g/s

Efficiency

78.5 %

Annual efficiency (EcoDesign)

68.5 %

PM

28 mg/m

3

OGC

120 mg/m

3

NOx

93 mg/m

3

CO at 13% O

2

1500 mg/m

3

CO at 13% O

2

0.12 %

Energy efficiency index

104

Energy efficiency class

A

Test result based on NS 3058

Particle emissions

-

The declaration of performance (DoP) can be downloaded from our website, www.hwam.com. 

Содержание I 30/65

Страница 1: ...User s manual EN 01 11 2020 97 9642 www hwam com I30 65 AUTOPILOT...

Страница 2: ...Drawings 4 6 Installation manual 8 Mounting and connection 10 Firing manual wood 12 Firing in general 14 Cleaning 15 Maintenance 16 Operational problems 18 Declaration of Performance 18 Product inform...

Страница 3: ...Page 3 of 20 pages 1 1 1 A1 A2 A3 7 8 5 6 5 4 3 2 1 b 40 4 cm 2 a 39 1 cm...

Страница 4: ...Page 4 of 20 pages B D C 2 1 3 5 4 3 6...

Страница 5: ...Page 5 of 20 pages E F G 1 1 1 2 2 H...

Страница 6: ...Page 6 of 20 pages...

Страница 7: ...he air control lever A window that can be opened or an adjustable air valve will be sufficient It must not be possible to block the adjustable air valve grate In newly built airtight dwellings we reco...

Страница 8: ...N 13240 measurement point If measured just above the smoke flue socket the chimney draught must be 18 20 Pa The chimney must have a minimum clearing of 150 mm The chimney must be provided with an eas...

Страница 9: ...duct and the smoke chamber above the baffle plate must be cleaned together with the chimney If the chimney is too tall to be cleaned from above it must be equipped with a soot door In case of a chimne...

Страница 10: ...ntre to fit tightly around the tube Place the fire tube in the chimney so that the joining flange corresponds to the given measurements a Distance from front edge of the brick hole if the insert must...

Страница 11: ...ng The frame of the outer casing has a width of 25 mm though only 20 mm at the top Any brick work stretching across the outer casing must be self supporting Remember the screws between the outer casin...

Страница 12: ...ce and pine are more easy to light up They burn faster and give off fewer ambers You may therefore take advantage of the light types of wood for lighting and use the heavier types of wood to ensure a...

Страница 13: ...sation forms on the glass for a maximum of 5 min Close the door When the kindling is burning well push the output regulating rod into middle position If the fire goes out this has been done too early...

Страница 14: ...sary to burn more wood How to achieve the best combustion Use clean and dry wood Wet wood results in inefficient combustion plenty of smoke and soot Furthermore the heat will dry the wood not heat up...

Страница 15: ...in halfway up pull out the top guide latches on the sides ease the glass pane into place and lead the guide latches back into place over the screws The inside of the glass pane is best cleaned with da...

Страница 16: ...with copper grease if necessary drawing B 1 Check the spring in the Autopilot unit and replace if necessary Checking gaskets Replace gaskets if they are not intact or are no longer soft Inspection of...

Страница 17: ...e door slides too easily the spring has loosened The spring can be loosened or tightened as follows Remove the insert from the outer casing Make sure the door of the combustion chamber 3 is closed Att...

Страница 18: ...open the door when there are still flames on the wood Uncontrollable combustion Faulty seal in door or ash pan Fit new seal If there is an excessive chimney draft it may be necessary to set the air co...

Страница 19: ...items in a way that is as sustainable as possible and that is in line with the current environmental protection reprocessing recycling and disposal technology Useful efficiency at nominal heat output...

Страница 20: ...www hwam com...

Отзывы: