51
Now .push .the .three .batts .up .around .the .fire .tube .and .press .them .up .into .the .chimney .thereby .achieving .
a .compact .and .tight-fitting .seal .
Installing the outer casing (Drawing A2)
If .you .would .like .to .mount .hoses .in .order .to .distribute .a .portion .of .the .convection .heat .to .other .rooms, .
push .the .two .plates .on .each .side .of .the .smoke .outlet .hole .on .the .casing .outwards .
(see drawing H)
.
Push .the .outer .casing .
(6)
.into .place .at .the .bottom .of .the .fireplace . .Carefully .ensure .that .the .outer .casing .
is .level .and .that .its .front .edge .is .flush .with .the .brickwork . .The .three .adjustment .screws .in .the .bottom .of .
the .casing .can .be .used .for .fine .adjustment .so .that .the .casing .is .completely .level .
(drawing F). Screw .the .
connector .to .the .building-in .cassette .with .the .help .of .the .self-tapping .screws .supplied .
If .the .gap .between .the .fireplace .aperture .and .the .outer .casing .is .to .be .closed .with .brickwork, .there .must .
be .a .minimum .distance .of .5 .mm .around .the .outer .casing .The .brickwork .above .the .outer .casing .must .
therefore .be .self-supporting . .Attach .the .casing .to .the .masonry .with .1-3 .screws .in .the .base .
Mounting the insert (Drawing A3)
Remove .the .smoke .shelf .
(7)
.from .the .insert . .Remove .the .smoke .deflector .plate .
(8)
.from .the .insert . . .
Attach .an .Ø6 .mm .seal .to .the .bottom .the .smoke .outlet .bushing . .Then .push .the .insert .into .place .in .the .
brickwork .casing . . .Push .the .inner .pipe .all .the .way .into .the .liner’s .smoke .outlet .connector . .Afterwards, .
remount .the .smoke .deflector .plate .
(8)
.and .smoke .shelf .
(7)
.
Seal .between .fire .tube .and .chimney .on .top .of .the .batts .using .heatproof .mortar .
(5)
. .This .can .be .done .
through .the .soot .door .
(1)
.of .the .chimney, .and .should .only .be .done .when .the .insert .is .assembled .
Connecting external supply of fresh air
The .HWAM .I .30/45 .can .be .connected .to .fresh .air .systems . .The .fresh .air .system .can .be .purchased .
separately . .
2. Restructuring of brickwork around insert
During .the .reconstruction, .the .outer .casing .should .be .carefully .levelled .off .at .a .suitable .height . .As .the .
reconstruction .progresses, .there .should .be .a .gap .of .min . .5 .mm .between .the .brickwork .and .the .outer .
casing . .The .frame .of .the .outer .casing .has .a .width .of .25 .mm, .though .only .20 .mm .at .the .top . . .Any .brick-
work .stretching .across .the .outer .casing .must .be .self-supporting . .Remember .the .screws .between .the .
outer .casing .and .the .wall .
Fire .tubes .and .any .convection .ducts .to .other .rooms .should .be .fitted .to .the .outer .casing .during .the .
reconstruction .
The .outer .casing .is .not .load-bearing . .Therefore, .fire .tubes .exceeding .2 .m .in .length .and, .possibly, .the .
chimney, .must .be .secured .(using .hangers) .thus .avoiding .putting .any .load .on .the .outer .casing .
When .the .reconstruction .has .been .completed, .mount .the .insert .as .described .in .point .1 .
Fitting the loose parts (Drawing C)
Before .you .start .using .the .insert, .you .must .ensure .that .all .loose .parts .are .fitted .correctly .
a . .Smoke .plate .
(1)
. .Must .lie .on .top .of .the .steel .rail .and .on .the .slanting .side .plates . .
b . .Steel .smoke .deflector .plate
(2)
. .Is .mounted .on .two .hooks . .To .mount .the .plate, .lift .it .up .and .lead .to .
the .right .until .it .is .hanging .on .the .two .hooks .