I
nStAllAtIon
In general
Congratulations on your new HWAM woodburning stove. We are pleased that you have chosen a HWAM
woodburning stove and confident that it will give you much pleasure. To ensure optimum operation and
safety, we recommend that the installation should be carried out by an authorised HWAM retailer or
a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under
“Retailer locations”.
Safety
The installation of your HWAM woodburning stove must always comply with all European, national and
local building regulations. The installation must be carried out in accordance with the instructions in the
installation and user manuals and subsequently registered with the local authorities. Upon installation,
the chimney sweep must approve the installation before you can start using the woodburning stove. All
HWAM woodburning stove packaging material must be handled in accordance with local waste manage-
ment regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the stove is to be installed. The
woodburning stove uses approx. 4-15 m
3
of air per hour. A window that can be opened or an adjustable
air valve will be sufficient. It must not be possible to block the adjustable air valve/grate. In newly built/
airtight dwellings, we recommend that a fresh air system should be installed for the direct supply of
external air to the combustion. This fresh-air system may be bought separately.
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand
the weight of the stove and the chimney. The weight of the chimney should be calculated according to
its dimensions and height.
Technical measures and data
Test results from nominal test EN 13240
Nominal heating effect
4,5 kW
Flue gas temperature EN 13240 measurement point
238ºC
Flue gas temperature measured in the outlet socket
307ºC
Exhaust gas flow
3,66 g/s
Efficiency
83,4 %
Annual efficiency (EcoDesign)
73,4 %
PM
20 mg/m
3
OGC
51 mg/m
3
NOx
108 mg/m
3
CO at 13% O
2
1000 mg/m
3
CO at 13% O
2
0,08 %
Energy efficiency index
111
Energy efficiency class
A+
Test result based on NS 3058
Particle emissions
2,45 g/kg
The declaration of performance (DoP) can be downloaded from our website, www.hwam.com.