HW Group I/O Controller 2 Скачать руководство пользователя страница 11

I/O Controller 2 Manual 

HW group 

 

 

www.HW-group.com

 

11/ 42

   

 

Setting up the device using TCP Setup 

 

 

Change to the “

TCP Client

” tab and enter the configured IP address. Set the 

TCP Port 

to 

99

 

Click “Connect”. The listing on the left displays the “

WEB51>

” prompt. Click inside this pane 

and press ENTER. The window displays the current configuration. 

 

To set a parameter, enter the 
corresponding letter and the desired 
value (for example “

I192.168.6.8

” to 

set the device IP address). To show 
the help for a command, enter the 
command and a question mark, and 
press ENTER 

– for example, “

I? 

<Enter>

“. All the settings are 

described in detail later in this 
manual. 

 

After setting the parameters, use R 
for 

Reboot

 

and press “Disconnect” 

to disconnect from the device. The 
device restarts.  
 

 

Note: TCP Setup can be disabled 
with 

the “Enable TCP setup” option. 

When unchecked, the device 
refuses connections to port 99. 

 

Setting up the device using a RS-232 terminal 

If you do not have Windows or our Hercules utility available, you can set up the device over RS-232 
using any terminal. 

 

Set 

DIP1 = ON

,   

DIP2 = OFF. 

 

Connect RS-232 (port 1) to a PC using the 
supplied 

LapLink

 cable. 

 

Open your favorite terminal program (e.g. 
Hyperterminal), choose the correct serial 
port and configure it to 

9600 8N1

 

Connect the power adapter to the 
electrical outlet and to the device. 

 

If the power is OK, the green 

Power

 LED 

lights up. 

 

If the serial cable and terminal program 
are working, the text menu for configuring 
the device appears.  

 
Continue by following the steps as in the previous 
case. 

Содержание I/O Controller 2

Страница 1: ...I O Controller 2 Manual HW group www HW group com 1 42 I O Controller 2 MANUAL...

Страница 2: ...llowing safety and maintenance instructions The device must not be used in particular under any of the following conditions The device is noticeably damaged The device does not function properly Unfas...

Страница 3: ...just like for example COM 5 a Windows XP Vista Windows 7 Server 2003 Server 2008 x64 driver is available free of charge Compatible with RFC2217 100 Mbps Ethernet interface 100BASE Tx RJ 45 Support fo...

Страница 4: ...e max 50V to power supply Sampling period 10 ms SW control of inputs and outputs Inputs and Outputs controlled over a NVT based M2M protocol extended RFC2217 short 7 byte binary commands over TCP IP O...

Страница 5: ...I O Controller 2 Manual HW group www HW group com 5 42...

Страница 6: ...troller 2 Manual HW group www HW group com 6 42 Connectors Connector pinout RS 485 Port Pin Signal A A B B RS 232 Port Pin Signal 1 CD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Cannon 9 Male Powe...

Страница 7: ...Serial port in the RS 232 mode OFF ON Serial port in the RS 485 mode check the R and H parameters recommended R3 H1 LEDs Power green External power connected LINK amber Ethernet interface activity Sta...

Страница 8: ...e This can be useful when you want to control a relay from this output O 0 to O 7 8 open collector outputs with common diode overvoltage protection The outputs a realized using 8 open collector transi...

Страница 9: ...tab click Find modules The MAC address of the device appears in the left column Click the MAC address and set the required parameters at least the IP address mask and gateway Make sure that Enable TC...

Страница 10: ...group com 10 42 Configuring the device over WWW In the UDP Setup tab click the correct MAC address and press Open in the WEB browser You need to log in to access the configuration The default password...

Страница 11: ...rs use R for Reboot and press Disconnect to disconnect from the device The device restarts Note TCP Setup can be disabled with the Enable TCP setup option When unchecked the device refuses connections...

Страница 12: ...he Hercules utility To invoke the menu right click inside the receiving pane or the transmitting pane At this point click Read in the lower right hand corner to read the inputs 8 switches at the test...

Страница 13: ...1 I need to supply power to a RS 232 application If you don t need to control data flow HW handshake but need to power a device connected to the serial port max 5 10 mA power your application from the...

Страница 14: ...ercules utility If not enable NVT and save the settings Start HW VSP and find the devices at the UDPsetup tab Select the MAC address of the device and click Use this IP Change to the Virtual SP tab Th...

Страница 15: ...data switches to Client mode and establishes the connection The incoming TCP server port is configured at the main Virtual SP tab We recommend using port numbers higher than 1025 Create port on start...

Страница 16: ...guration Command description The description of the settings combines WWW based configuration and TCP serial setup Some functions are only available in serial TCP setup TEA security settings QUIT mode...

Страница 17: ...I O Controller 2 Manual HW group www HW group com 17 42 Network parameters TCP Setup Mode...

Страница 18: ...I O Controller 2 Manual HW group www HW group com 18 42...

Страница 19: ...range defined by the converter s IP address and the mask In IP Setup W Address 0 0 0 0 IP address of a network or a computer that is allowed to communicate with the device This value must be the resu...

Страница 20: ...This means that if no TCP IP connection is established and the device either receives serial port data even a single byte or the state of its digital inputs changes in the range allowed by the T opti...

Страница 21: ...ode 0 Off do not use telnet control codes pass through to serial port 1 On accept telnet control codes Note With NVT off it is not possible to control the digital inputs and outputs and the SETUP does...

Страница 22: ...for the serial line Any speed from 50 to 115 200 Bd can be set To set 9600 Bd enter B9600 The resolution depends on the speed Up to about 1000 Bd 1 Bd steps can be used At 10 kBd only 100 Bd steps are...

Страница 23: ...rity enter PS V1 space parity variable parity on S Stop bits 2 Number of stop bits for the serial communication As a rule there should be at least 9 bits and at most 10 bits in total excluding the sta...

Страница 24: ...00 Bd or 5 7 ms at 19200 Bd G Char Transmit Delay 0 Off When controlling devices with a small RS232 buffer it is sometimes advantageous to keep a relatively high baud rate but insert delays between in...

Страница 25: ...embedded into the TCP IP data stream along the serial port data However these commands only appear in the Ethernet communication they never pass through to the serial port In recent firmware versions...

Страница 26: ...mode Passive mode is used and the connection is closed nothing happens If the connection is open data are send through the open connection Note Even if the input states are not transmitted to the rem...

Страница 27: ...ge of digital output values that can be influenced by the states of inputs retrieved from the remote side after RESET D Power Up XOR mask 0 The binary XOR function is suitable inverting individual out...

Страница 28: ...t states from a PC because the I O Controller supports only one TCP connection at a time As long as a TCP connection to the other I O Controller is established the I O Controller cannot be accessed fr...

Страница 29: ...essible in the menu K1 H0 enables periodic state transmission only when nothing else is sent e g data from the serial port K1 H1 enables periodic state transmission approximately every 5 seconds regar...

Страница 30: ...tates to corresponding outputs at a specified remote device The inputs to mirror are defined by the edge mask I O edge mask R Rise edge mask 255 Defines the inputs that will be monitored for rising ed...

Страница 31: ...4024 When the UDP GPIO Control mode is enabled I O Controller sends the state changes to the specified address and port V GPIO control from COM Off When enabled I O Controller inputs and outputs can b...

Страница 32: ...tores settings from slot 2 2 Stores current settings to slot 1 3 Stores current settings to slot 2 R Reboot Software restart Necessary e g when the IP address is changed Recommended after changing par...

Страница 33: ...oller 2 Manual HW group www HW group com 33 42 UDP IP mode settings When T IP mode UDP is chosen the device will communicate with the remote party using UDP packets Also the following menu appears in...

Страница 34: ...tern 58 0 0 0 Start trigger condition for packet transmission Four bytes are set however only the number of bytes specified in L Trigger Length is considered M Start Trigger Mask 255 0 0 0 Mask of the...

Страница 35: ...ast 4 bytes to the displayed value use K3 0D 0E 0F 10 The key is used to verify one time passwords OTP when authenticating the remote side Other device parameters Q Quiet Batch mode Quiet mode is usef...

Страница 36: ...W group com 36 42 What s new in the WEB interface IO Control Read inputs and control outputs Outputs can be controlled either by entering a decimal value 0 255 corresponding to the output states or by...

Страница 37: ...I O Controller 2 Manual HW group www HW group com 37 42 Firmware upgrade Upgrades the current device firmware This operation may change some settings...

Страница 38: ...riable Parity Off S Stop bits 1 C Flow Control None R RTS Output continuously asserted 8V A DTR Output unasserted 8V T Serial Line Timeout 0 Off G Char Transmit Delay 0 Off H Tx Control Tx FULL duplex...

Страница 39: ...H Tx Control Tx FULL duplex Security Setup A TCP autorisation Off K TEA key 0 01 02 03 04 1 05 06 07 08 2 09 0A 0B 0C 3 0D 0E 0F 10 S TCP IP setup On I O Control Setup T Trigger AND mask 255 A Power U...

Страница 40: ...at both devices If security is an essential requirement and the device should only communicate within the local network use the following settings In this case only communication within the LAN segmen...

Страница 41: ...t pins of the I O Controller Our extension is not standardized however when we implemented this extension in 2001 no such standard was known to us How does it work The commands are control sequences i...

Страница 42: ...icited response without a matching request Theoretically this command can be used in NVT communication too It differs from sub option 51 in that the value sent to the port is modified with X Y Z W I O...

Страница 43: ...set one output bit to logic LOW without changing other output bits Outgoing sequence FF FA 2C 32 25 FF F0 I O Controller returns FF FA 2C 97 DF FF F0 where DF is the actual output port value also depe...

Страница 44: ...ection To keep the connection alive and avoid the 50 second inactivity timeout use the K Keep connection option in the device setup NVT must be enabled for this to work The connection is kept alive by...

Отзывы: