10
External Magnetic Field
:
<
40A/m
External Electric Field
:
<
1V/m
Measuring Time
: 1 second
Resistance Measurement Frequency
:
>
1KHz
Maximum Resistance Measurement Resolution
: 0.001 Ω
Resistance Measurement Range
: 0.01-1000 Ω
*Current Measuring Range
: 0.00-30.0A
* Measured Current Frequency
: 50/60Hz
* Storable Measurement Data
: 99 Units
*Setting Range of Resistance Alarm Critical Value
: 1-199 Ω
*Setting Range of Current Alarm Critical Value
:
1-499mA
Note: "*" is limited to ETCR2000C.
IV. Structure of Meter
1. Liquid Crystal Display (LCD)
2. Trigger
: to control opening and closing of jaw :
3. Pincer Jaw
: 55 x 32mm
4. POWER Key
: Boot Up / Shutdown /
*
Quit
5. HOLD Key
: lock / Release display
*6.MODE Key
: switch key of function mode (resistance measurement /
current measurement /data access)