Huvitz HS-5000 5X Скачать руководство пользователя страница 45

-------------------------------------------------------------------------------------SLIT LAMP 

HS-5000 5X

  45

 

14. Service Information

How to contact service: If there are any problems with the equipment, please follow the 

steps below: 

z

 

First of all, refer to the 10. Maintenance and 11. Troubleshooting sections according 

to the problem that you are encountered. And then follow the suggested sequences.   

z

 

If the problem persists, please contact the local distributor in your province or country 

at first.   

z

 

Before calling to the local distributor, you’d better check these information such as 

Model and Serial Numbers. To do so, fill up the following table as soon as you   

purchase our product. You can look up these information at any time. The serial 

number is found on the back of this unit. The serial number is unique to this unit. 

You should retain this manual as a permanent record of your purchase. Please retain 

your purchase receipt as your proof of purchase.   

Date of Purchase: 

Dealer’s Name: 

Dealer Address: 

Dealer Phone No. : 

Model No.: 

Serial No.: 

z

 

If you can’t contact with your local distributor, you can directly get in touch with the 

service department of the HUVITZ using the phone number and the address written 

in the below table.   

Содержание HS-5000 5X

Страница 1: ...SLIT LAMP HS 5000 5X 1 Operator s Manual SLIT LAMP MICROSCOPE HS 5000 5X...

Страница 2: ...se of equipment in rated voltage less than 125Vac minimum 6A Type SJT or SVT 18 3AWG 10A max 3 0m long One end with Hospital Grade Type NEMA 5 15P Other end with appliance coupler For use of equipment...

Страница 3: ...not required to update this documentation to reflect such changes 2006 HUVITZ Co Ltd 689 3 Geumjeong dong Gunpo si Gyeonggi do 435 862 Republic of Korea All rights are reserved Under copyright laws th...

Страница 4: ...7 2 2 Safety Symbols 8 2 3 Environment factors 10 2 4 Safety Precautions 12 3 Features Operating Condition 14 3 1 Brief Description 14 3 2 Operating Condition 14 4 Standard Components 16 5 Accessorie...

Страница 5: ...and manufacturer s declaration electromagnetic immunity 34 11 3 Guidance and manufacturer s declaration electromagnetic immunity 36 11 4 Recommended separation distances between portable and mobile R...

Страница 6: ...bio microscopic examination of the eye 1 2 Classification Protection against electric shock Class I Applied Parts Type B applied parts Protection against harmful ingress of water Ordinary IPX0 Degree...

Страница 7: ...ator It is for this reason that the following safety notices have been placed appropriately within the text of this manual to highlight safety related information or information requiring special emph...

Страница 8: ...symbol printed explicitly on the product label or sticker Save this instruction I and O on power switch represent ON and OFF respectively Type B Isolated patient connection This symbol identifies a sa...

Страница 9: ...ean Directive 2002 96 EC All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the...

Страница 10: ...wet hand Where the equipment is exposed to direct sunlight Where the temperature changes extremely Normal operating temperature range is from 10 C to 40 C Humidity is from 30 to 75 Altitude is from 7...

Страница 11: ...power cord into the outlet before the connection between devices of the equipment is completed This can generate the defect Pull out the power cord with holding the plug not the cord Avoid places wher...

Страница 12: ...his device in humid rooms Humidity should be maintained between 30 and 75 for normal operation Do not expose the device to water splashes dripping water or sprayed water Do not place containers contai...

Страница 13: ...s for persons operating and maintaining the equipment 11 Do not force cable connections If a cable does not connect easily be sure that the connector plug is appropriate for the receptacle socket If y...

Страница 14: ...o microscopic examination of the eye 3 2 Operating Condition z As long as the slit lamp is in its original package it can be exposed to the following environmental conditions for up to 15 weeks for sh...

Страница 15: ...iance and the exposure time If the value of radiance were reduced in half twice the time would be needed to reach the maximum exposure limit While no acute optical radiation hazards have been identifi...

Страница 16: ...h orthogonal movements 17 A sliding plate for the position device 19 A drawer 16 z A base with orthogonal movements z A microscope with either dual magnification or a system 31 including eyepieces z A...

Страница 17: ...llowing standard accessories are provided with the instrument z protection cover 46 z a setting rod 43 z spare bulbs 12V 30W Halogen bulb 53 z chin rest paper 47 z spare fuses 250Vac T2 0AL z a breath...

Страница 18: ...ateral longitudinal and vertical movements x y z 10 Base with orthogonal movements 11 Shaped tabletop 12 Warning light indicating the ignition of the SMPS is on 13 Main switch Warning light 14 Luminos...

Страница 19: ...for horizontal tilting 36 Control lever for vertical tilting 37 Microscope position stop 38 Graduated ring 90 0 90 determining the inclination of the slit during rotation 39 Lamp cover 40 fuse slots 4...

Страница 20: ...LAMP HS 5000 5X 54 Bulb fastening knob 55 Mirror 56 Capture connector For the image system 57 Capture switch 58 Luminosity selector connector Connect the Luminosity selector to the SMPS 59 Head rest...

Страница 21: ...SLIT LAMP HS 5000 5X 21 Figure 2 Composition I...

Страница 22: ...22 SLIT LAMP HS 5000 5X Figure 3 Composition...

Страница 23: ...p to all kinds of transport and standard storage conditions Please contact the suppliers if any irregularities are found in the appliance due to transport after unpacking 7 1 Assembling the Instrument...

Страница 24: ...e with orthogonal movements on the guides situated on the upper part of the table top checking that the wheels are in line Then Place the crankcase 59 and make sure that its holes fit together with th...

Страница 25: ...10 Then tighten the Guide screw with the screw driver z Put the microscope 31 in the right position making sure that it is placed well in the stop 37 then tighten it with the knob 34 situated the righ...

Страница 26: ...26 SLIT LAMP HS 5000 5X Figure 6 Assembling the instrument...

Страница 27: ...is forehead against the forehead rest z Lift or lower the chin rest by moving the handle 25 so that the patient s eyes are in line with the notches on the chin rest 29 z Switch the instruments on pres...

Страница 28: ...5X 40X 5 enlargements model z Tilting 5 10 15 20 z Microscopy of the back part and of the posterior vitreous body by means of the Hruby lens or a contact options Goldman lens z Observation of the eye...

Страница 29: ...NOTE Don t touch any other parts of glass tube with the bare fingers Fingerprints if any must be wiped off from the glass tube with alcohol 10 1 Halogen Projection bulb To replace the Halogen project...

Страница 30: ...gers z Fasten the bulb with the knob z Make sure that the stems of the bulb are completely inserted insert the plug in the main supply socket Don t Touch to the Lamp House During the Operation It s He...

Страница 31: ...ced on the back of the SMPS and inserted power socket Before doing anything else disconnect the plug from the main supply socket z Remove the burned out fuses z Substitute the fuses and check z Replac...

Страница 32: ...b the body and the probe once a month Do not use lacquer thinner ethylene or the oxidizing substance z If the instrument is not in use dust must be kept away by covering the instrument with the suppli...

Страница 33: ...RF Emissions CISPR 11 Group 1 The EUT uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment...

Страница 34: ...1kV for input output lines 2kV for power supply lines 1kV for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1kV differential...

Страница 35: ...uptible power supply or a battery Power frequency 50 60Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels character ristic of a typical location in a typic...

Страница 36: ...nment guidance Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 Vrms 150 kHz to 80MHz 3 V m 80 MHz to 2 5GHz 3 Vrms 150 kHz to 80MHz 3 V m 80MHz to 2 5GHz Portable and mobile RF communications e...

Страница 37: ...d people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot b...

Страница 38: ...80MHz 80MHz to 800MHz 800MHz to 2 5GHz Rated maximum output power of transmitter W V1 3Vrms E 1 3V m E 1 3V m 0 01 0 116 0 1166 0 2333 0 1 0 368 0 3687 0 7378 1 1 166 1 1660 2 3333 10 3 687 3 6872 7...

Страница 39: ...1 5 Immunity and Compliance Level Immunity test IEC 60601 Test Level Actual Immunity Level Compliance Level Conducted RF IEC 61000 4 6 3Vrms 150kHz to 80MHz 3Vrms 3Vrms Radiated RF IEC 61000 4 3 3Vrms...

Страница 40: ...6 Radiated RF IEC 61000 4 3 3 Vrms 150 kHz to 80MHz 3 V m 80 MHz to 2 5GHz 3 Vrms 150 kHz to 80MHz 3 V m 80MHz to 2 5GHz The EUT must be used only in a shielded location with a minimum RF shielding ef...

Страница 41: ...dio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environme...

Страница 42: ...42 SLIT LAMP HS 5000 5X 12 Electric Diagram...

Страница 43: ...16x 25x 40x Real field of view 38 5 22 2 15 2 10 5 6 7 mm Interpupillary adjust 55 80 mm SLIT ILLUMINATION Slit length 0 3 12 mm continuous Slit width 0 12 mm continuous Slit projection 1x Aperture di...

Страница 44: ...nt Min 28mm Longitudinal Movement Min 78mm Lateral Movement Min 98mm Fine base Movement Min 10mm Power supply 100 240 V AC 50 60HZ 2 0A Power consumption 70VA Instrument Voltage 12V DC Halogem Project...

Страница 45: ...eck these information such as Model and Serial Numbers To do so fill up the following table as soon as you purchase our product You can look up these information at any time The serial number is found...

Страница 46: ...5X How to Contact HUVITZ Co Ltd Write us at HUVITZ Co Ltd Huvitz B D 689 3 Geumjeong dong Gunpo si Gyeonggi do South Korea 435 862 Tel 82 31 442 8868 Fax 82 31 442 8619 URL http www huvitz com e mail...